A Comprehensive, Three-Dimensional Analysis of a Large-Scale, Multi-Fuel, CFB Boiler Burning Coal and Syngas. Part 2. Numerical Simulations of Coal and Syngas Co-Combustion

Abstract: This paper presents the results of numerical computations for a large-scale OFz-425 CFB (circulating fluidized bed) boiler utilizing coal and syngas. Four different operating scenarios are considered, including the reference variant, corresponding to the conventional, mono-combustion of bituminous coal, and three tests involving replacement of secondary air and part of the coal stream with syngas fed by start-up burners. Pressure, gas velocity, temperature, and carbon dioxide distribution in the combustion cha… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
9
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 26 publications
(12 citation statements)
references
References 33 publications
(37 reference statements)
0
9
0
Order By: Relevance
“…The operating parameters have a non-linear, inter-dependent, and complex relationship with the η thermal [26]. An extensive set of assumptions should be made to help derive the analytical equations for such a complicated process analytically, and thereby, the correct response of the process cannot be accurately described [27,28].…”
Section: Introductionmentioning
confidence: 99%
“…The operating parameters have a non-linear, inter-dependent, and complex relationship with the η thermal [26]. An extensive set of assumptions should be made to help derive the analytical equations for such a complicated process analytically, and thereby, the correct response of the process cannot be accurately described [27,28].…”
Section: Introductionmentioning
confidence: 99%
“…Over the past few decades, researchers and energy experts are closely collaborating in a wide range of research activities to mitigate the harmful impacts of power generation to ensure sustainable power generation and environmental protection. [2][3][4][5][6][7][8][9][10][11][12][13][14][15][16].…”
Section: Introductionmentioning
confidence: 99%
“…The good performance of the developed CFD model was achieved. The maximum relative error was lower than The developed CFD model was successfully validated against experimental data [54]. The good performance of the developed CFD model was achieved.…”
Section: Validationmentioning
confidence: 78%
“…Figure 19 shows the comparison between the measured and calculated pressures and temperatures. The developed CFD model was successfully validated against experimental data [54]. The good performance of the developed CFD model was achieved.…”
Section: Validationmentioning