2021
DOI: 10.3390/coatings11080924
|View full text |Cite
|
Sign up to set email alerts
|

Use of Digital Image Correlation Method to Measure Bio-Tissue Deformation

Abstract: Traditionally, strain gauge, extensometer, and reflection tracking markers have been used to measure the deformation of materials under loading. However, the anisotropy and inhomogeneity of most biological materials restricted the accessibility of the real strain field. Compared to the video extensometer, digital image correlation has the advantage of providing full-field displacement as well as strain information. In this study, a digital image correlation method (DIC) measurement system was employed for chic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(5 citation statements)
references
References 31 publications
0
2
0
Order By: Relevance
“…In this study, β, ϕ, and ∅ were assumed 0 • , 45 • , and 90 • . The strain ε y , γ xy , and ε y are taken by DIC analysis [15,28,29]. The stress can be calculated for a thin film by Equations ( 4) and ( 5):…”
Section: Methods Of Residual Stress Measurementmentioning
confidence: 99%
See 2 more Smart Citations
“…In this study, β, ϕ, and ∅ were assumed 0 • , 45 • , and 90 • . The strain ε y , γ xy , and ε y are taken by DIC analysis [15,28,29]. The stress can be calculated for a thin film by Equations ( 4) and ( 5):…”
Section: Methods Of Residual Stress Measurementmentioning
confidence: 99%
“…In this study, the area was selected in the center of core Figure 7 of 81 × 81 pixels in size. In this case, the second-order fitting method was applied to the full-field displacement by using Matlab (2009, Natick, MA, USA) according to the research [15,28,29]. The SEM image drift, spatial distortion, and magnification variations throughout the calibration protocol refer to our previous study [28].…”
Section: Methods Of Residual Stress Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…The experimental approach adopted in the present study was informed by the imaging methodology used by Seghir and Pierron . This method supported the use of digital image correlation (DIC), an experimental mechanics technique used to resolve high strain rate deformations in materials, which has also been applied in some biological studies although at lower imaging frequencies. , Overall, the design criteria for the developed apparatus included the need to support cell culture within a fluid chamber that could allow for the microbubble interaction with cells. In addition, the device had to support a reliable and tunable acoustic field that replicated interaction dynamics similar to those in therapeutic and clinical studies.…”
Section: Introductionmentioning
confidence: 99%
“…Alice [ 8 ] used DIC to measure the elastic modulus of skeletal tissue and verified the related results of DIC by four-extensometer technique. Chen Y F [ 17 ] combined an optical parameter measurement system with DIC to analyze the relationship between biological tissue strain changes and optical parameters. Thus, when the Young’s modulus of biological tissue is known, the relative optical parameters such as stress factor can be characterized.…”
Section: Introductionmentioning
confidence: 99%