2001
DOI: 10.1016/s0168-9002(01)00652-0
|View full text |Cite
|
Sign up to set email alerts
|

Upgrading of the PETRA-2 beamline at HASYLAB for materials science analyses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2003
2003
2022
2022

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 4 publications
0
6
0
Order By: Relevance
“…Three other samples were investigated on the beamline PETRA II at HASYLAB, Hamburg, Germany [22], with a similar experimental arrangement, since the two beamlines share the same general layout. Those samples were pre-aged at 1270 K for 25h and 100h and at 1120 K for 150h (and quenched to freeze their microstructure).…”
Section: Methodsmentioning
confidence: 99%
“…Three other samples were investigated on the beamline PETRA II at HASYLAB, Hamburg, Germany [22], with a similar experimental arrangement, since the two beamlines share the same general layout. Those samples were pre-aged at 1270 K for 25h and 100h and at 1120 K for 150h (and quenched to freeze their microstructure).…”
Section: Methodsmentioning
confidence: 99%
“…By putting a similar camera in the far field it becomes possible to record a high-resolution image of the diffraction spot (Kampmann et al, 2001;Bö hm et al, 2003) and to resolve the angular difference between the and 0 peaks (Fig. 6).…”
Section: Dcdmentioning
confidence: 99%
“…By putting a camera in the far field, following a diffraction spot with high angular accuracy and in real time becomes possible (Kampmann et al, 2001;Bö hm et al, 2003). The aim of this paper is to describe this double-crystal diffractometry (DCD) setup and to give some preliminary results on hightemperature creep tests with fast transients on a model material: AM1 Ni-base single-crystal superalloy (Caron & Lavigne, 2011).…”
Section: Introductionmentioning
confidence: 99%
“…Alternatively, ring sections can be recorded more accurately by putting larger area detectors further away. Such a configuration has been established by using wire-frame gas detectors at the PETRA-II beamline at HASYLAB (Kampmann et al, 2001). of the angles (, , !) into a pole figure (, ) can be found in the literature (Bunge and Klein, 1996).…”
Section: Texture and Stress Analysismentioning
confidence: 99%
“…In particular two detectors can be used in order to still acquire two dimensions of the strain field. However, in a greater distance the requests regarding spatial resolution of the detectors is relaxed and position sensitive gas detectors as developed by DENEX 2 can be employed (Kampmann et al, 2001;Marmotti et al, 2002). Those detectors are not isotropic and the position resolving wires are oriented radially to the Debye-Scherrer ring in order to receive a resolution of about 1 mm.…”
Section: Texture and Stress Analysismentioning
confidence: 99%