2019
DOI: 10.1109/tim.2019.2907733
|View full text |Cite
|
Sign up to set email alerts
|

Uncertainty Analysis Method Including Influence of Probe Alignment on On-Wafer Calibration Process

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 23 publications
(13 citation statements)
references
References 30 publications
0
13
0
Order By: Relevance
“…The following step is wafer probing, which is the procedure of electrically verifying each die on a wafer. This is accomplished by utilizing an automatic wafer probing system, which is actively searching for functional defects through by employing special test patterns [56][57][58]. The next step, semiconductor packaging and assembly process, involves enclosing ICs and encompasses from die-attach adhesives to liquid and film-shaped encapsulation compounds, sealing, lead forming/trimming, deflash, wirebonding, lead finish to heat-conducting materials, and conductive and non-conductive adhesives for sensors, among others.…”
Section: Semiconductor Manufacturing Processmentioning
confidence: 99%
“…The following step is wafer probing, which is the procedure of electrically verifying each die on a wafer. This is accomplished by utilizing an automatic wafer probing system, which is actively searching for functional defects through by employing special test patterns [56][57][58]. The next step, semiconductor packaging and assembly process, involves enclosing ICs and encompasses from die-attach adhesives to liquid and film-shaped encapsulation compounds, sealing, lead forming/trimming, deflash, wirebonding, lead finish to heat-conducting materials, and conductive and non-conductive adhesives for sensors, among others.…”
Section: Semiconductor Manufacturing Processmentioning
confidence: 99%
“…A fully automatic probe station was constructed to apply the RSD technique. The details of the probe station have been published previously [22][23][24][25][26]. The measurements were conducted in two frequency bands, which ranged from 1 GHz to 110 GHz (100 GHz band) and from 220 GHz to 325 GHz (300 GHz band).…”
Section: A Measuring Instrumentsmentioning
confidence: 99%
“…Hence, it is important to readjust the probe tilt angle to minimize damage to the contact pads when the measurement position is moved far from the previous device position. Furthermore, because the thru standard has a dominant effect on calibration quality [23], the measurement of the thru standard was set to the latter process in the mTRL calibration procedure, as listed in Table II. The total processing time was approximately 2 h. Successive calibration and verification processes were repeated five times from October 2018 to March 2020.…”
Section: Precision Probe Alignment Techniquementioning
confidence: 99%
See 1 more Smart Citation
“…Unfortunately, moving the probe can cause inaccuracies in the RF calibration. This was investigated in [32] [10] and [33]. The authors from [32] recommend to plot the inductance and the phase (see Fig.…”
Section: Control Of Experimental Parametersmentioning
confidence: 99%