2014
DOI: 10.1002/adfm.201402191
|View full text |Cite
|
Sign up to set email alerts
|

Ultrasensitive Detection of Mitochondrial DNA Mutation by Graphene Oxide/DNA Hydrogel Electrode

Abstract: 6905wileyonlinelibrary.com of DNA. The bionic structure benefi ts the adsorption and hybridization of DNA. [ 3 ] The intermediate conductivity of electrode is sensitive to the change of conductivity introduced by trace DNA on the surface of electrode. On the contrary, this weak change is unobvious for the electrode with too high or low conductivity. As is well known, the conductivity of semiconductor silicon can be increased by adding certain impurities in minute quantities. Graphene oxide (GO) is a semiconduc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
35
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 43 publications
(35 citation statements)
references
References 43 publications
0
35
0
Order By: Relevance
“…24,25 GO hydrogel was prepared based on our previous work except that no fish sperm DNA was added. 23 A total of 0.5 mL of 4.05 mg/mL GO was dropped into a 2 mL conicalbottom centrifuge tube, which was heated at 95°C for 1 h in a thermomixer and cooled down to room temperature to form GO hydrogel. Similarly, 4.05 mg/mL GO, 1.25 mM HAuCl 4 , and 1.2 mM NaBH 4 were thoroughly mixed in a centrifuge tube and then heated at 95°C for 1 h before cooling down to form GO/GNPs hydrogel.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…24,25 GO hydrogel was prepared based on our previous work except that no fish sperm DNA was added. 23 A total of 0.5 mL of 4.05 mg/mL GO was dropped into a 2 mL conicalbottom centrifuge tube, which was heated at 95°C for 1 h in a thermomixer and cooled down to room temperature to form GO hydrogel. Similarly, 4.05 mg/mL GO, 1.25 mM HAuCl 4 , and 1.2 mM NaBH 4 were thoroughly mixed in a centrifuge tube and then heated at 95°C for 1 h before cooling down to form GO/GNPs hydrogel.…”
Section: Methodsmentioning
confidence: 99%
“…The detection limit of our biosensor is lower than that of the other electrochemical or spectrometric methods for AβO detection based on PrP C probe (Table S2) due to the following possible reasons: first, EIS is a powerful electrochemical technology for the detection of small changes occurring at biosensor surfaces. Second, the bionic structure of the soft hydrogel with abundant water provides a friendly interface 23 In addition, the 3D porous structure of hydrogel has enormous space and allows rapid penetration of biomolecules into the electrode, which benefits the adsorption and binding of AβO.…”
Section: Electrochemical Impedance Assays For Aβo Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…36,37 Lysine (Lys) and FA were purchased from Sangon Biotech (Shanghai, China). All MoS 2 samples were prepared from an original batch of the bulk materials.…”
Section: Preparation Of Go Mos 2 /Go Nanocomposites and Mos 2 Derivamentioning
confidence: 99%
“…The conductivity of this hydrogel can be tuned by varying the GO's properties. Moreover, this hydrogel electrode showed potential for the deduction of ovarian cancer cells DNA samples [29]. DNA immobiliized on GO glassy electrode nanocomposite was proposed for the detection of acrylamide (AA).…”
Section: +mentioning
confidence: 99%