2007
DOI: 10.1002/ccd.21361
|View full text |Cite
|
Sign up to set email alerts
|

Transcatheter closure of atrial septal defect with Amplatzer® device in children aged less than 10 years old: Immediate and late follow‐up

Abstract: Secundum atrial septal defect closure can be safely and successfully performed with the Amplatzer septal occluder in children younger than 10 years old.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
22
0
1

Year Published

2009
2009
2015
2015

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(25 citation statements)
references
References 106 publications
2
22
0
1
Order By: Relevance
“…The procedure is safe, effective and reproducible in different hands, even for patients with more complex anatomies such as multifenestrated and/or aneurysmal septum, large defects and those associated with deficient rims 141516171819202122. Because children with secundum ASDs are usually asymptomatic, with normal weight gain and limited respiratory repercussion (repeat infections or wheezing, or both), the procedure is preferentially performed when the patient weighs over 20 kg.…”
Section: Outcomes After Medical Surgical or Interventional Treatmentmentioning
confidence: 99%
See 1 more Smart Citation
“…The procedure is safe, effective and reproducible in different hands, even for patients with more complex anatomies such as multifenestrated and/or aneurysmal septum, large defects and those associated with deficient rims 141516171819202122. Because children with secundum ASDs are usually asymptomatic, with normal weight gain and limited respiratory repercussion (repeat infections or wheezing, or both), the procedure is preferentially performed when the patient weighs over 20 kg.…”
Section: Outcomes After Medical Surgical or Interventional Treatmentmentioning
confidence: 99%
“…Because children with secundum ASDs are usually asymptomatic, with normal weight gain and limited respiratory repercussion (repeat infections or wheezing, or both), the procedure is preferentially performed when the patient weighs over 20 kg. Several devices have been used including the Buttoned device, Amplatzer Septal Occluder (AGA Medical, Plymouth, Minnesota, USA), Helex (WL Gore and Associates, Flagstaff, Arizona, USA) and Intrasept (Cardia, Eagan, Minnesota, USA) 141516171819202122. The experience with the CardioSEAL/Starflex/Biostar (NMT Medical, Boston, Massachusetts, USA) device has been limited in South America.…”
Section: Outcomes After Medical Surgical or Interventional Treatmentmentioning
confidence: 99%
“…Also in recent years, using alternative approaches, it was implemented the percutaneous or transapical of aortic valve implants and endovascular devices, such as aortic endoprosthesis and rings for annular reduction for mitral valve and devices for occlusion of congenital atrioventricular defects [4][5][6]8].…”
Section: Discussionmentioning
confidence: 99%
“…In these examples, are included the aortic stents, devices for occlusion of congenital clefts (Amplatzers) and transcatheter aortic valve implants [4][5][6][7][8].…”
Section: Introductionmentioning
confidence: 99%
“…These findings have been confirmed even with the usage of various kinds of devices and in different patients’ age group. [4567] Some studies have even demonstrated a significant functional improvement of ASD in patients with mild (RV) dilatation and lower systolic pulmonary arterial pressure (SPAP). [8]…”