2000
DOI: 10.1016/s0009-9120(00)00177-6
|View full text |Cite
|
Sign up to set email alerts
|

Total Plasma Malondialdehyde Levels in 16 Taiwanese College Students Determined by Various Thiobarbituric Acid Tests and an Improved High-Performance Liquid Chromatography-based Method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

4
98
0
10

Year Published

2003
2003
2019
2019

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 138 publications
(112 citation statements)
references
References 27 publications
4
98
0
10
Order By: Relevance
“…Within physiological systems, MDA may exist in a free state or in a protein-bound form; various studies have looked at the relative proportions of MDA in human plasma and have reported that between 83% and 92% of the MDA is protein bound ( 17,18 ). Hydrolysis of the protein-bound MDA fraction may be achieved by either an alkaline treatment ( 18,19 ) or an acid treatment ( 20 ) of the sample prior to the acid-catalyzed TBA reaction.…”
Section: Validation Of the Tbars And Mda Assaysmentioning
confidence: 99%
“…Within physiological systems, MDA may exist in a free state or in a protein-bound form; various studies have looked at the relative proportions of MDA in human plasma and have reported that between 83% and 92% of the MDA is protein bound ( 17,18 ). Hydrolysis of the protein-bound MDA fraction may be achieved by either an alkaline treatment ( 18,19 ) or an acid treatment ( 20 ) of the sample prior to the acid-catalyzed TBA reaction.…”
Section: Validation Of the Tbars And Mda Assaysmentioning
confidence: 99%
“…The HPLC-based method with fluoresence detection (515 nm excitation, 555 nm emission) of plasma TBA-MDA was reported in an earlier report 19) . First, 0.25 ml of plasma was added to 1.5 ml of methanol/acetic acid (3:2 v/v) that contained 1% KI and 0.025 ml of 0.2% BHT (in 95% ethanol).…”
Section: Plasma Mda Assaymentioning
confidence: 99%
“…Bound malondialdehyde (MDA) in plasma was released from protein with 10 N NaOH, reacted with thiobarbituric acid (TBA) at 951C for 30 min, and the MDA-TBA complex analyzed by reverse-phase HPLC (Hewlett Packard 1100, Palo Alto, CA) with fluorescence detection as described. [15][16][17] Plasma total homocysteine, cysteine and cysteinylglycine Plasma concentrations of total homocysteine, cysteine and cysteinylglycine were determined with reverse-phase HPLC using a C18 column on a Waters HPLC instrument equipped with a WISP automatic injector and attached to a fluorimeter (Applied Sciences Inc., Dayton, OH). as described by Araki and Sako.…”
Section: Gpx 3 and Nitrotyrosinementioning
confidence: 99%