2000
DOI: 10.1016/s0002-8703(00)90077-2
|View full text |Cite
|
Sign up to set email alerts
|

Three-dimensional echocardiographic assessment of annular shape changes in the normal and regurgitant mitral valve

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

7
107
2
5

Year Published

2006
2006
2019
2019

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 170 publications
(121 citation statements)
references
References 19 publications
7
107
2
5
Order By: Relevance
“…2,9,10 This improved technology demonstrates a sequence of normal mitral annulus conformational changes over the cardiac cycle. Although atrial contraction may theoretically affect annular shape, no change occurred between early and late diastole.…”
Section: D Dynamics Of the Normal Annulusmentioning
confidence: 99%
See 1 more Smart Citation
“…2,9,10 This improved technology demonstrates a sequence of normal mitral annulus conformational changes over the cardiac cycle. Although atrial contraction may theoretically affect annular shape, no change occurred between early and late diastole.…”
Section: D Dynamics Of the Normal Annulusmentioning
confidence: 99%
“…Nevertheless, the depth of knowledge about mitral annular physiology is limited. Pilot studies performed 3D reconstruction of mitral structure, particularly with MR induced by ischemia 8,9 or cardiomyop-athy. 10 However, the annular geometry and dynamics with MR resulting from myxomatous valve disease (MVD) are uncertain, 11 despite the importance of annuloplasty in surgical treatment.…”
mentioning
confidence: 99%
“…Many studies report that mitral apparatus changes may contribute to ischemic mitral regurgitation (MR); however the main mechanism is still under controversy [1][2][3][4][5]. An optimal surgical approach to ischemic MR has not been reached yet as the exact MR mechanism remains unknown.…”
Section: Introductionmentioning
confidence: 99%
“…Estas implicaciones son las que se tienen en cuenta actualmente para el diseño y selección de prótesis mitral anular (Kaplan et al 2000), así que la variación fundamental se hizo en la forma y se conservaron las dimensiones básicas. En el modelo este ajuste nos llevó a una longitud de cuerda de 8.7 cm, valor que está en el rango experimental, ya que de acuerdo a información reportada por Ormiston et al (1981) los valores de cuerda en la válvula mitral fluctúan entre 7.0 y 10.5.…”
Section: El Modelo Anatómico De Aurícula Normalunclassified