2011
DOI: 10.1590/s0100-69162011000600002
|View full text |Cite
|
Sign up to set email alerts
|

Thermal comfort indices in individual shelters for dairy calves with different types of roofs

Abstract: Among the building materials used in rural facilities, roofs are noteworthy for being largely responsible for thermal comfort, influencing the thermal balance within the shelter. This study aimed to evaluate the influence of roof on the Enthalpy (H), Thermal Load of Radiation (TLR), and Black Globe Temperature and Humidity Index (BGHI) in individual shelters for dairy calves. The design was completely randomized with three treatments: Z -zinc tile, AC -asbestoscement tile and ACW -asbestos-cement tile painted … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

1
1
0
2

Year Published

2015
2015
2018
2018

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 10 publications
(8 reference statements)
1
1
0
2
Order By: Relevance
“…Abreu et al (2011) observed lower IST for fiber cement tiles in relation to metallic tiles at 14h. Fonseca et al (2011) also verified similar results when studying fiber cement tiles and zinc tiles, where fiber cement tile presented better thermal efficiency than the metallic tile studied (zinc). Sampaio et al (2011) studied the superficial temperature of roofing and their relation to the building thermal environment.…”
Section: Resultssupporting
confidence: 80%
“…Abreu et al (2011) observed lower IST for fiber cement tiles in relation to metallic tiles at 14h. Fonseca et al (2011) also verified similar results when studying fiber cement tiles and zinc tiles, where fiber cement tile presented better thermal efficiency than the metallic tile studied (zinc). Sampaio et al (2011) studied the superficial temperature of roofing and their relation to the building thermal environment.…”
Section: Resultssupporting
confidence: 80%
“…Variação média diária da temperatura de bulbo seco (Tbs, °C) no interior dos abrigos nos diferentes tratamentos e no abrigo meteorológico nos dias de maior (A) e menor entalpia (B), temperatura crítica inferior (TCI), zona de conforto térmico (ZCT) e temperatura crítica superior (TCS) para bezerros Não houve diferença estatística (p > 0,05) entre os tipos de cobertura e o ambiente externo para o ITGU; no entanto e de acordo com Baêta & Souza (2010) os valores verificados (Tabela 1) indicam condição de conforto (ITGU < 74) para os bovinos, proporcionado pelo efeito do sombreamento promovido pela cobertura. O valor do ITGU obtido no abrigo com cobertura de fibrocimento está dentro do intervalo encontrado por Sampaio et al (2011) entre 64,2 e 73,5 e menores que os obtidos por Fonseca et al (2011) que avaliaram coberturas de telha de zinco (81,63); telha de cimento amianto (77,41) e telha de cimento amianto pintada de branco na face superior (76,84), em abrigos individuais para bezerros leiteiros.…”
Section: Resultsunclassified
“…Tais valores foram inferiores aos encontrados por Fonseca et al (2011) que verificaram valor mínimo de 63,94 e máximo de 70,38 kJ kg -1 ar seco, principalmente pela baixa umidade relativa do ar entre as 10 e 16 h (Figura 4A).…”
Section: Resultsunclassified
“…However, FONSECA et al (2011) found a statistical difference between treatments when assessing facilities with tiles of zinc, asbestos cement, and asbestos cement white painted on the upper face. These authors observed that the lowest values of RHL and BGHI (489.28 W m −2 and 76.8, respectively) were found in facilities covered with asbestos cement tiles white painted on the upper face whereas the highest values were found in facilities with zinc tiles (523.55 W m −2 and 81.6, respectively).…”
Section: Resultsmentioning
confidence: 89%