Proceedings of the 16th ACM Great Lakes Symposium on VLSI 2006
DOI: 10.1145/1127908.1127915
|View full text |Cite
|
Sign up to set email alerts
|

Thermal analysis of a 3D die-stacked high-performance microprocessor

Abstract: 3-dimensional integrated circuit (3D IC) technology places circuit blocks in the vertical dimension in addition to the conventional horizontal plane. Compared to conventional planar ICs, 3D ICs have shorter latencies as well as lower power consumption, due to shorter wires. The benefits of 3D ICs increase as we stack more die, due to successive reductions in wire lengths. However, as we stack more die, the power density increases due to increasing proximity of active (heat generating) devices, thus causing the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

6
63
0
1

Year Published

2007
2007
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 132 publications
(71 citation statements)
references
References 28 publications
6
63
0
1
Order By: Relevance
“…As an example, the reported operating temperature of a central processing unit (CPU) can reach temperatures as high as 150 °C [8][9][10] . However, the oxidation behavior of copper at a temperature below 300 °C has received little attention.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…As an example, the reported operating temperature of a central processing unit (CPU) can reach temperatures as high as 150 °C [8][9][10] . However, the oxidation behavior of copper at a temperature below 300 °C has received little attention.…”
Section: Discussionmentioning
confidence: 99%
“…Copper has been widely used as bonding wires or interconnects within many electronic components. Due to increasing component density and decreasing line width, the temperature within an electronic device may reach a temperature above 200 °C during operation [8][9][10] . In this study, the oxidation behavior of copper at 200 °C and 300 C in air is investigated.…”
Section: Introductionmentioning
confidence: 99%
“…The modeling parameters and thermal constants for each layer are as described in [2,26] and reproduced in Table 3. The heat sink is placed close to the bottom Table 3.…”
Section: Methodsmentioning
confidence: 99%
“…Many have focused on improving single-core performance and power [2,7,26,44]. Some of this attention has focused on implementing a cache in 3D [25,29,40], even in the context of a multi-core NUCA layout [16].…”
Section: Related Workmentioning
confidence: 99%
“…As illustrated in the analysis of a 3-D die-stacked microprocessor implementation by Puttaswamy et al [26], stacking identical multi-processor dies may obstruct heat transfer to the heat-sink resulting in a noticeable, yet limited, overall temperature increase of the system. In the extreme case of being unable to provide adequate heat dissipation for a 3-D die-stacked implementation, a number of solutions have been proposed.…”
Section: A Homogeneous and Modular Approachmentioning
confidence: 99%