2015
DOI: 10.1109/jsen.2014.2362940
|View full text |Cite
|
Sign up to set email alerts
|

The Rogowski Coil Principles and Applications: A Review

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
64
0
3

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
3
1

Relationship

0
9

Authors

Journals

citations
Cited by 159 publications
(67 citation statements)
references
References 41 publications
0
64
0
3
Order By: Relevance
“…The initial electron concentration n drl0 can be obtained from [19] ) ( . Since the collector current density J c is directly proportional to the load current I L , the duration Δt 3 increase with I L is revealed by (18). While a Δt 2 decreases with the I L for fixed V dc and T j is revealed by (10) and (22).…”
Section: Duration δT 3 Dependence Analysismentioning
confidence: 94%
See 1 more Smart Citation
“…The initial electron concentration n drl0 can be obtained from [19] ) ( . Since the collector current density J c is directly proportional to the load current I L , the duration Δt 3 increase with I L is revealed by (18). While a Δt 2 decreases with the I L for fixed V dc and T j is revealed by (10) and (22).…”
Section: Duration δT 3 Dependence Analysismentioning
confidence: 94%
“…In terms of TSEPs v th and v gp , they are unlikely for the online extraction because of their low sensitivity (About few millivolts per degree [11]) and sensitive sensing circuit requirements. Additional components are needed to convert dynamic dv/dt and di/dt to an observable signal, like RC circuitry or a PCB Rogowski coil, which affect IGBT switching characteristics [17][18]. Particularly, the turn-on current of IGBT intertwined with the reverse recovery current of corresponding diode in the commutation circuits, thus di/dt (max) during the turn-on interval may not reflect the IGBT junction temperature accurately.…”
Section: Introductionmentioning
confidence: 99%
“…We create the model of the current bar by segmenting analytic curves, which we covered with a thickness and width in order to obtain a 3-D model. The fourth basic element is the PLC coupling element, the Rogowski coil, as illustrated in Fig 4. Usually, Rogowski coils are used as measurement elements for alternating current in a conductor [32]- [34], but Rogowski coils can be also used as PLC coupling elements [15], [35]. The most important advantage is that Rogowski coils are air-cored, as a result of which saturation effects cannot occur.…”
Section: B Extended Channel Modelmentioning
confidence: 99%
“…With the rapid development of smart grid and widely launch of intelligent substations, the shift to digitization in the power system made present-day metering and protection devices not need large power drive any more. Rogowski coils applied in current measurement in intelligent substations adapt to the development tendency and they are in extensive application at present stage [11].…”
Section: Introductionmentioning
confidence: 99%