The measurement of gas–liquid two-phase flows in a small diameter pipe using a dual-sensor multi-electrode conductance probe

Abstract: We design a dual-sensor multi-electrode conductance probe to measure the flow parameters of gas–liquid two-phase flows in a vertical pipe with an inner diameter of 20 mm. The designed conductance probe consists of a phase volume fraction sensor (PVFS) and a cross-correlation velocity sensor (CCVS). Through inserting an insulated flow deflector in the central part of the pipe, the gas–liquid two-phase flows are forced to pass through an annual space. The multiple electrodes of the PVFS and the CCVS are flush-mo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
15
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 40 publications
(17 citation statements)
references
References 52 publications
0
15
0
Order By: Relevance
“…The probe response value was obtained when the total flowrate of gas and water was 300 m 3 /d and the total flowrate of oil and water was 30 m 3 /d, and interpolation imaging was gathered. Through the comparison and analysis of the literature research, this article adopts a simple distance inverse weighting, which is more effective in the ring array instrument interpolation algorithm [12][13][14][15]. The water holdup of the wellbore section was calculated through the holdup diagram, and then the comparison and analysis were performed.…”
Section: Data Interpolation Imaging Analysismentioning
confidence: 99%
“…The probe response value was obtained when the total flowrate of gas and water was 300 m 3 /d and the total flowrate of oil and water was 30 m 3 /d, and interpolation imaging was gathered. Through the comparison and analysis of the literature research, this article adopts a simple distance inverse weighting, which is more effective in the ring array instrument interpolation algorithm [12][13][14][15]. The water holdup of the wellbore section was calculated through the holdup diagram, and then the comparison and analysis were performed.…”
Section: Data Interpolation Imaging Analysismentioning
confidence: 99%
“…For conductance sensors, a gas phase will also affect the measurement. Zhai et al [5] designed a dual-sensor multi-electrode conductance probe to measure the flow parameters of gas-liquid two-phase flow. However, these methods all require the design of a new type of flowmeter, which balloons flow measurement costs.…”
Section: Introductionmentioning
confidence: 99%
“…Additionally, Transfer Entropy (TE) exists, which allows identification of a cause-effect relationship by not accounting for straightforward and uniquely shared information [15]. TE has been applied to many complex problems from diverse research fields e.g., oscillation analysis [16], finance [17,18], sensors [19][20][21][22], biosignals [23,24], thermonuclear fusion [25], complex networks [26], geophysical phenomena [27,28], industrial energy consumption network [29] and algorithmic theory of information [30]. In addition, TE has been implemented in non-Gaussian distributions, such as: multivariate exponential, logistic, Pareto (type I-IV) and Burr distributions [31].…”
Section: Introductionmentioning
confidence: 99%