2018
DOI: 10.1093/rpd/ncy154
|View full text |Cite
|
Sign up to set email alerts
|

The German Dose Rate Monitoring Network and Implemented Data Harmonization Techniques

Abstract: Environmental radiation monitoring networks have been established in Europe and world-wide for the purpose of protecting population and environment against ionizing radiation. Some of these networks had been established during the cold war period and were improved after the Chernobyl accident in 1986. Today, the German Federal Office for Radiation Protection (BfS) operates an early warning network with roughly 1800 ambient dose equivalent rate (ADER) stations equally distributed over the German territory. The … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
4
2
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 20 publications
(7 citation statements)
references
References 13 publications
0
7
0
Order By: Relevance
“…We propose to answer this question in this paper; this can be achieved thanks to the Germany REWS System [2], which offer their data to run all experiments; we thank all the experts we are in contact with, to validate or invalidate the results found by applying the different time series clustering algorithms. The data used in this work comprise the past ten years minute-by-minute gamma dose rate real data for over a thousand probes.…”
Section: Context and Problem Statementmentioning
confidence: 99%
“…We propose to answer this question in this paper; this can be achieved thanks to the Germany REWS System [2], which offer their data to run all experiments; we thank all the experts we are in contact with, to validate or invalidate the results found by applying the different time series clustering algorithms. The data used in this work comprise the past ten years minute-by-minute gamma dose rate real data for over a thousand probes.…”
Section: Context and Problem Statementmentioning
confidence: 99%
“…For the purpose of ADR data harmonization, it is worth mentioning projects such as AIRDOS, MetroERM (http:// earlywarning-emrp.eu/, last access: 1 July 2019), EGNRS-WG, and INTERCAL (Schauinsland, BfS). The EURDEP system was upgraded in the past years by the so-called AIR-DOS extension (Bossew et al, 2007), which provided detailed information on European dose-rate-monitoring networks focusing on probe characteristics, e.g. the sensitivity and other physical properties.…”
Section: Ambient Dose Ratementioning
confidence: 99%
“…While many of the data have previously been used for various purposes within refereed or scientific applications (e.g. Bossew et al, 2012Szegvary et al, 2007), complete datasets for specific radiological events (e.g. De Cort et al, 2019a, b) have never been integrally published.…”
Section: Introductionmentioning
confidence: 99%
“…The German BfS developed a simplified site characteristic correction that would allow strongly reducing the measurement deviations caused by the site-specific effects (Stöhlker et al, 2019). It is planned to implement this simplified site characteristic correction in a future EURDEP web-site version so that users can optionally select a view that applies this correction method to obtain a better inter-comparability of the measurements.…”
Section: Ambient Dose Ratementioning
confidence: 99%