1972
DOI: 10.1016/s0003-2670(00)86852-x
|View full text |Cite
|
Sign up to set email alerts
|

The determination of lead in blood by atomic absorption with the high-temperature graphite tube

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...

Citation Types

0
3
0

Year Published

1974
1974
1982
1982

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 25 publications
(3 citation statements)
references
References 6 publications
0
3
0
Order By: Relevance
“…Recent developments of flameless atomic absorption offer the opportunity for the direct determination of trace metals in biological materials requiring microliter sample volumes. Among the non-flame atomization methods proposed for lead determinations on 100 µ or less are atomic absorption by graphite sample cells e.g., carbon rod, graphite tube (2)(3)(4)(5)(6)(7)(8), by the tantalum strip (9), and the flame atomization techniques using a sampling cup (10) or sampling boat (11). For cadmium determination, the r.f.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…Recent developments of flameless atomic absorption offer the opportunity for the direct determination of trace metals in biological materials requiring microliter sample volumes. Among the non-flame atomization methods proposed for lead determinations on 100 µ or less are atomic absorption by graphite sample cells e.g., carbon rod, graphite tube (2)(3)(4)(5)(6)(7)(8), by the tantalum strip (9), and the flame atomization techniques using a sampling cup (10) or sampling boat (11). For cadmium determination, the r.f.…”
mentioning
confidence: 99%
“…However, a number of these methods cannot be considered as direct methods since there is need for external ashing of the sample or for solvent extraction (8)(9)(10)13). Besides, in most cases the use of a deuterium background corrector is recommended or necessary (2-7, 9, 11, 14).…”
mentioning
confidence: 99%
“…prior to analysis with the attendant risk of contamination or loss of trace constituents. The Delves-cup technique has been successfully used for blood analysis but the application has been essentially limited to Pb determinations(80,107,108).Several authors have described the use of flameless atomization devices for the determination of trace elements in biological fluids(73,79,83,(102)(103)(104)(105)(106). In some Instances prior separation of the metal is required while.…”
mentioning
confidence: 99%