The Approach of Including TVOCs Concentration in the Indoor Environmental Quality Model (IEQ)—Case Studies of BREEAM Certified Office Buildings

Abstract: The article analyzes the impact of measured concentrations of Total Volatile Organic Compounds (TVOC) emissions determined for four BREEAM certified buildings on the Indoor Air Quality Index (IAQindex) and the overall Indoor Environment Quality index (IEQindex). The IEQindex indicates the percentage of building users who are satisfied from the indoor environment. In existing IEQ models, currently the concentration of CO2 is mostly used to evaluate the IAQindex sub-component. Authors point out that it is recomm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
47
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 29 publications
(49 citation statements)
references
References 36 publications
1
47
0
Order By: Relevance
“…The VOCs were identified by the mass spectral database. The mean of total VOCs concentration (TVOC) was 120 µg/m 3 ± 18%, which corresponds to a neutral percentage of dissatisfaction (PD TVOC < 5%) in accordance to Reference [47].…”
Section: The Measuring Equipmentsupporting
confidence: 72%
“…The VOCs were identified by the mass spectral database. The mean of total VOCs concentration (TVOC) was 120 µg/m 3 ± 18%, which corresponds to a neutral percentage of dissatisfaction (PD TVOC < 5%) in accordance to Reference [47].…”
Section: The Measuring Equipmentsupporting
confidence: 72%
“…Sub-component models were developed and presented in the literature [5,22] based on sensory studies in panel groups. This included research by the author [23,24]. For a physical parameter (e.g., light intensity or volatile organic compound concentration in indoor air), the corresponding satisfaction index was calculated by formulas (1)(2)(3)(4)(5)(6)(7)(8)(9)(10) provided in this section.…”
Section: Ieq Model and Sub-components Used For A Building Assessmentmentioning
confidence: 99%
“…The simplified scheme of the assessment model developed during the period 2016-2019 is presented in Figure 1. The previous version of Figure 1 was published by the authors of [23].…”
Section: Ieq Model and Sub-components Used For A Building Assessmentmentioning
confidence: 99%
See 2 more Smart Citations