The quest for a sustainable built environment brought dramatic changes to architectural design because of the integrated design process. The integrated design process is the modern way to realize “performance architecture,” that is, design with a view to field performance. Integrated design process permits merging of concepts from passive-house designs, solar engineering, and an integration of the building enclosure with mechanical services. In part 1 of this series, the emergence of many new multi-functional materials was discussed. Yet, current innovation is guided by lessons from history. Thermal mass in heavy masonry buildings allowed periodic heating. The authors postulate integration of a hydronic heating system with the walls and the use of smart temperature control of the heating system to modify and optimize the thermal mass contribution. To use the mass of a building, one must accept transient temperature conditions where the indoor temperature varies but is confined by comfort requirements for both summer and winter conditions. On the other side, resiliency requirements dictate that in the absence of electricity the air temperature does not fall below about 12°C over a period of several hours. This requirement implies that summer cooling will likely be separated from the heating systems and that operation of a low-energy building is heavily dependent on the design of smart control systems. Analysis of control systems provided in this article for earth-to-air heat exchangers and cooling of houses with lightweight walls lead us to the requirements of separation between heating and ventilation and needs for different sources of fresh air. Finally, a new concept emerges.
Designing and constructing near zero energy buildings (NZEBs) is a challenge not only from a structural point of view, but also from the point of view of ensuring appropriate climate comfort for users. The standards describing how to ensure comfort were created in times when the challenges of building ZEB/NZEB were not yet explored and energy issues were not as important as they are today. Therefore, the assessment of the thermal and climatic comfort of people living and working in such buildings requires a new or revised approach to the methodology of thermal comfort assessment. In this article, the authors present the results of a thermal comfort study based on measurements and thermal sensory tests. Testing was carried out in an experimental office building (passive standard). The main goal of the experiment was to compare the thermal comfort measurement method based on the ISO-Fanger model with the actual comfort results obtained by the panellists in the model office condition. The tests allowed the lowest operating temperature providing thermal comfort (predicted mean vote (PMV) = 0 and −0.5) to be determined. Sensory tests were conducted using three types of questions. The results were compared to the other researchers’ findings. It was noted that the panellists showed better thermal comfort sensation at lower temperatures than would result from the traditional Fanger distribution, so the authors proposed the experimental function of percentage of dissatisfied (PPD) = f(PMV). The authors hope that it contributed to the actual state of knowledge as a “small and specific scale” validation of the existing thermal comfort model. The results also revealed that the method of heating has an influence on the subjective thermal sensation.
The Directive 2010/31/EU on the energy performance of buildings has introduced the standard of “nearly zero-energy buildings” (NZEBs). European requirements place the obligation to reduce energy consumption on all European Union Member States, particularly in sectors with significant energy consumption indicators. Construction is one such sector, as it is responsible for around 40% of overall energy consumption. Apart from a building’s mass and its material and installation solutions, its energy consumption is also affected by its placement relative to other buildings. A proper urban layout can also lead to a reduction in project development and occupancy costs. The goal of this article is to present a method of optimising single-family house complexes that takes elements such as direct construction costs, construction site organisation, urban layout and occupancy costs into consideration in the context of sustainability. Its authors have analysed different proposals of the placement of 40 NZEBs relative to each other and have carried out a multi-criteria analysis of the complex, determining optimal solutions that are compliant with the precepts of sustainability. The results indicated that the layout composed of semi-detached houses scored the highest among the proposed layouts under the parameter weights set by the developer. This layout also scored the highest when parameter weights were uniformly distributed during a test simulation.
The growing popularity of buildings with integrated sub-systems requires a review of methods to optimize the preheating of ventilation air. An integrated system permits using geothermal heat storage parallel to the direct outdoor air intake with additional treatment in the mechanical room as a part of building an automatic control system. The earth–air heat exchanger (EAHX) has many advantages but also has many unanswered questions. Some of the drawbacks are: A possible entry of radon gas, high humidity in the shoulder seasons, and the need for two different air intake sources with a choice that depends on the actual weather conditions. In winter the EAHX may be used continuously to ensure thermal comfort, while in other seasons its operation must be automatically controlled. To generate missing information about EAHX technology we examined two nearly identical EAHX systems, one placed in the ground next to a building and the other under the basement slab. In another project, we reinforced the ground storage action by having a heat exchanger placed on the return pipes of the hydronic heating system. The information provided in this paper shows advantages of merging both these approaches, while the EAHX could be placed under the house or near the basement foundation that is using an exterior basement insulation.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.