2019
DOI: 10.1016/j.molliq.2019.111478
|View full text |Cite
|
Sign up to set email alerts
|

Tetrahydroacridines as corrosion inhibitor for X80 steel corrosion in simulated acidic oilfield water

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 61 publications
(17 citation statements)
references
References 32 publications
0
17
0
Order By: Relevance
“…In order to understand the structural analysis of the metal surface, morphological images were taken by three different methods. Metal microscopy ( Figure 10) [60], FE-SEM at 200 times magnification ( Figure 11) [61] and AFM images (Figure 12 and Figure 13) [62] were evaluated. All morphologies were realized in 1.0 M HCl solutions with and without 1.0×10 -4 M DMT at a temperature of 298 K and an immersion time of 120 hours.…”
Section: Structural Surface Morphology Findingsmentioning
confidence: 99%
“…In order to understand the structural analysis of the metal surface, morphological images were taken by three different methods. Metal microscopy ( Figure 10) [60], FE-SEM at 200 times magnification ( Figure 11) [61] and AFM images (Figure 12 and Figure 13) [62] were evaluated. All morphologies were realized in 1.0 M HCl solutions with and without 1.0×10 -4 M DMT at a temperature of 298 K and an immersion time of 120 hours.…”
Section: Structural Surface Morphology Findingsmentioning
confidence: 99%
“…This is mainly due to the presentation of inhibitor molecules in the solution, where a quasi-substitution process takes place, replacing the profoundly dielectric nature of water particles with the low dielectric natural inhibitor molecule and in-time it expands in thickness. 40 Accordingly, this would prevent the formation of the electric double layer and decrease the number for transferred electrons, which decreases the CR. We can account for these changes through the Helmholtz model eq 4 for the calculation of the double-layer capacitance.…”
Section: Resultsmentioning
confidence: 99%
“…The double-layer capacitance might have been diminished altogether by increasing the Pz series inhibitor concentration. This is mainly due to the presentation of inhibitor molecules in the solution, where a quasi-substitution process takes place, replacing the profoundly dielectric nature of water particles with the low dielectric natural inhibitor molecule and in-time it expands in thickness . Accordingly, this would prevent the formation of the electric double layer and decrease the number for transferred electrons, which decreases the CR.…”
Section: Resultsmentioning
confidence: 99%
“…In addition, the shape or size of the corrosion inhibitor molecule has a great impact on its performance (El Azzouzi et al, 2016;Zarrouk et al, 2016;Salim et al, 2019;Meeusen et al, 2020;Mishra et al, 2020). As seen previously, heterocyclic compounds have been studied by many researchers such as benzimidazoles, quinoxaline, oxazole, imidazole, quinoline, and tetrazole (Zhang et al, 2019a;Zhang et al, 2019b;El-Hajjaji et al, 2019;Qiang et al, 2020;Qiang et al, 2021). In addition, with the increase in the number of unsaturated bonds in the molecules, the corrosion inhibition performance of these compounds is improved.…”
Section: Introductionmentioning
confidence: 93%