1989
DOI: 10.1109/20.22608
|View full text |Cite
|
Sign up to set email alerts
|

Testing of a rapid-fire compensated pulsed alternator system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

1989
1989
2011
2011

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 26 publications
(8 citation statements)
references
References 2 publications
0
8
0
Order By: Relevance
“…UT-CEM was testing the first U.S. Army prototype iron core compulsator (CPA) when dramatic performance increases appeared as a result of moving from plasma to solidhybrid armatures [3]. The benefit in efficiency, particularly at lower velocities (under 4 km/s) had also been studied and verified by others including Barber [4].…”
Section: Ilp Design Methodologymentioning
confidence: 99%
See 1 more Smart Citation
“…UT-CEM was testing the first U.S. Army prototype iron core compulsator (CPA) when dramatic performance increases appeared as a result of moving from plasma to solidhybrid armatures [3]. The benefit in efficiency, particularly at lower velocities (under 4 km/s) had also been studied and verified by others including Barber [4].…”
Section: Ilp Design Methodologymentioning
confidence: 99%
“…The model for this design was assembled and executed in FORTRAN and results were compared to many earlier designs [1][2][3][4][5][6][7][8][9][10][11]. For the purpose of validation, an ambiguous 2,300 m/s launch package was designed and validated using a dynamic 3D mechanical finite element analysis.…”
Section: Model Example Design and Preliminary Verificationmentioning
confidence: 99%
“…Among the potential applications for railguns rapid fire systems have been discussed for a long time [1][2][3][4][5]. In fact the electric launch technology may outclass classical powder guns not only with respect to muzzle energy but also regarding the maximal cadences to be obtained.…”
Section: Introductionmentioning
confidence: 99%
“…Nevertheless, the problem of matching the parameters between ACPA and the flashlamp load is complicated. References [5,6,7] are based on the experimental data of the particular compensated pulsed alternators. References [10,11] have already calculated and analyzed the characteristic parameters of current waveform of ACPA, as well as the parameters of machine effecting.…”
Section: Introductionmentioning
confidence: 99%