2015
DOI: 10.1007/s11468-015-0108-y
|View full text |Cite
|
Sign up to set email alerts
|

Temperature-Regulated Surface Plasmon Resonance Imaging System for Bioaffinity Sensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 14 publications
(4 citation statements)
references
References 34 publications
0
4
0
Order By: Relevance
“…Beyond multiplexed array detection, SPRi has been applied toward the study of bacterial films, adhesion, and mobility using the visualization capabilities offered by the technique. 45−47 Advances in SPRi instrumentation have ranged from the conservative, yet undoubtedly important end, with integrated temperature control and monitoring demonstrated, 48,49 to the more radical, including variations on traditionally used monochromatic light sources and CCD cameras. Researchers desiring both the high dynamic ranges of spectroscopic SPR and the throughput capabilities of SPRi have sought after technical solutions that allow for both, with their studies converging on wavelength interrogation for collected array images.…”
Section: ■ Platforms and Instrumentationmentioning
confidence: 99%
“…Beyond multiplexed array detection, SPRi has been applied toward the study of bacterial films, adhesion, and mobility using the visualization capabilities offered by the technique. 45−47 Advances in SPRi instrumentation have ranged from the conservative, yet undoubtedly important end, with integrated temperature control and monitoring demonstrated, 48,49 to the more radical, including variations on traditionally used monochromatic light sources and CCD cameras. Researchers desiring both the high dynamic ranges of spectroscopic SPR and the throughput capabilities of SPRi have sought after technical solutions that allow for both, with their studies converging on wavelength interrogation for collected array images.…”
Section: ■ Platforms and Instrumentationmentioning
confidence: 99%
“…The utilization of SPR in gas detection has garnered significant attention due to its label-free and real-time characteristics [9,10]. However, most SPR sensors rely on measuring the intensity change in the reflected beam, which is susceptible to environmental influences and exhibits a low sensitivity to changes in the refractive index of small molecules [11,12].…”
Section: Introductionmentioning
confidence: 99%
“…The biosensors can be distinguished two main types by methods of signal generation such as bioaffinity sensors and biocatalytic biosensors. The bioaffinity sensors are defined that the biological device bound with test object to occur bioaffinitive binding result in the change of the biomolecular shape or change of physical quantities such as charge, thickness, mass, heat, or optics [1]. The biocatalytic biosensors are defined that immobilized molecules react with the test object to generate biochemical metabolites [2].…”
Section: Introductionmentioning
confidence: 99%