1995
DOI: 10.6028/nist.ir.5632
|View full text |Cite
|
Sign up to set email alerts
|

Tables of x-ray mass attenuation coefficients and mass energy-absorption coefficients 1 keV to 20 MeV for elements Z = 1 to 92 and 48 additional substances of dosimetry interest

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

43
1,775
5
40

Year Published

2006
2006
2017
2017

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 1,938 publications
(1,863 citation statements)
references
References 1 publication
43
1,775
5
40
Order By: Relevance
“…In order to track secondary electrons down to 100 eV, and obtain shorter simulation execution times compared to the Geant4-DNA Low Energy Extensions, the Low Energy Electromagnetic Physics models based on PENELOPE [32][33][34] were adopted to describe particle interactions. Stewart et al [33] showed that PENELOPE physics models can estimate physical quantities on the micron-scale between 1 and 25% 50 µm agreement with track structure Monte Carlo codes when calculating the mean specific energy.…”
Section: Methodology: the Geant4 Simulation Studymentioning
confidence: 99%
See 1 more Smart Citation
“…In order to track secondary electrons down to 100 eV, and obtain shorter simulation execution times compared to the Geant4-DNA Low Energy Extensions, the Low Energy Electromagnetic Physics models based on PENELOPE [32][33][34] were adopted to describe particle interactions. Stewart et al [33] showed that PENELOPE physics models can estimate physical quantities on the micron-scale between 1 and 25% 50 µm agreement with track structure Monte Carlo codes when calculating the mean specific energy.…”
Section: Methodology: the Geant4 Simulation Studymentioning
confidence: 99%
“…The 67.4 keV K-edge [34] in Ta short-range, high LET photoelectrons. However, there is no increase of dose in the valley due to the limited range of the electrons.…”
Section: ) Statistical Uncertainty Is Present Though Smaller Than mentioning
confidence: 99%
“…Table 7.1: X-ray mass attenuation coefficients for carbon, nitrogen, and oxygen at 400 keV from Ref. [31]. The small differences in attenuation due to the presence of nitrogen and oxygen in seaweed are negligible when calculating self absorption of 131 I gamma rays in seaweed samples approximated as 100% carbon.…”
Section: Determination Of 131 I Detection Efficiencymentioning
confidence: 99%
“…For subsequent calculations, for which more data points with more precision were desired, 5 cm increments of thickness were instead used. In accordance with data provided [7], the concrete (ordinary or barite concrete) was specified as having the atomic composition given in Table I and a density. The source was a monoenergetic beam of photons of energy E, emitted perpendicularly from a disk 50 cm in radius, oriented axially in-line with the long axis of the cylindrical shield (as in Fig.…”
Section: Geometry and Materialsmentioning
confidence: 99%
“…Firstly, the attenuation of 0.511 MeV and 0.662 MeV photons by concrete is considered, and results compared with the standard measured data provided in the literature [5][6][7]. Good agreement is taken to indicate that the chosen Monte Carlo method may be employed to make additional calculations on the attenuation of sources with different energies, a capability particularly useful in cases where no analogous experimental data exist.…”
Section: Introductionmentioning
confidence: 99%