2013
DOI: 10.1016/j.nima.2012.09.041
|View full text |Cite
|
Sign up to set email alerts
|

Systematic study of particle quenching in organic scintillators

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 24 publications
(10 citation statements)
references
References 24 publications
0
10
0
Order By: Relevance
“…Phase boundary estimates derived from the emission wavelength and emission intensity curves were in good accord at ω 0,T = 0.40 (8) and ω 0,T = 0.44(9), respectively. Analogous wavelength and intensity data for the TW-h series found the phase boundary at ω 0,T = 0.50 (16) and ω 0,T = 0.55 (27), respectively.…”
Section: Methodsmentioning
confidence: 62%
See 1 more Smart Citation
“…Phase boundary estimates derived from the emission wavelength and emission intensity curves were in good accord at ω 0,T = 0.40 (8) and ω 0,T = 0.44(9), respectively. Analogous wavelength and intensity data for the TW-h series found the phase boundary at ω 0,T = 0.50 (16) and ω 0,T = 0.55 (27), respectively.…”
Section: Methodsmentioning
confidence: 62%
“…1−7 A precise knowledge of the counting efficiency is essential to fundamental measurements of radioactivity, so any loss of energy by a decay product (e.g., a β-particle or Auger electron) that does not produce scintillation light introduces a potential problem in radionuclide metrology. While we recently demonstrated that the micelle size effect is extremely small, 7 it is clear that other micelle effects, including changes in transmission of scintillation photons, 8 will still be important in LSC experiments. The most drastic changes of this type might occur when crossing a boundary such as a critical micelle concentration (cmc) separating two optically distinct phases.…”
Section: Introductionmentioning
confidence: 98%
“…For the radioactivity measurements, Pico Prias polyethylene vials of 6 mL (Perkin Elmer, USA) were used to prepare the samples using the following active stock solutions: a low-energy beta emitter, 3 …”
Section: Methodsmentioning
confidence: 99%
“…The counting time in the Quantulus for the blank, 3 H, 14 C and 241 Am samples was 60 min and 90 min for the 90 Sr/ 90 Y samples. The measurement of the external standard quenching parameter SQP(E) was fixed at 10 min.…”
Section: Measurementsmentioning
confidence: 99%
See 1 more Smart Citation