Suspended trapping procedure for alleviation of space charge effects in gas chromatography/Fourier-transform mass spectrometry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
21
0

Year Published

1992
1992
2015
2015

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 30 publications
(21 citation statements)
references
References 22 publications
0
21
0
Order By: Relevance
“…In addition, pulsing collision gas into the ICR trap significantly decreases the duty cycle (spectrum acquisition rate) of the FTICR instrument if high performance is to be maintained. Other ion cooling approaches include ion evaporative [55], adiabatic [36,38], resistive [56] and sympathetic [57] cooling. Though these approaches have been shown to provide effective cooling for particular applications, they have not been widely adopted because of a decrease in signal intensity (e.g., evaporative cooling), reduced capability of ion cooling over a broad m/z range (e.g., adiabatic cooling), inefficiency at higher cyclotron frequencies where detection is mostly capacitive (e.g., resistive cooling) or extended cooling time for hot heavier ions to be cooled by electrons (e.g., sympathetic cooling).…”
Section: Direct Infusion Experimentsmentioning
confidence: 99%
“…In addition, pulsing collision gas into the ICR trap significantly decreases the duty cycle (spectrum acquisition rate) of the FTICR instrument if high performance is to be maintained. Other ion cooling approaches include ion evaporative [55], adiabatic [36,38], resistive [56] and sympathetic [57] cooling. Though these approaches have been shown to provide effective cooling for particular applications, they have not been widely adopted because of a decrease in signal intensity (e.g., evaporative cooling), reduced capability of ion cooling over a broad m/z range (e.g., adiabatic cooling), inefficiency at higher cyclotron frequencies where detection is mostly capacitive (e.g., resistive cooling) or extended cooling time for hot heavier ions to be cooled by electrons (e.g., sympathetic cooling).…”
Section: Direct Infusion Experimentsmentioning
confidence: 99%
“…Although this difference is relatively large, we had reason to believe that a sufficient population of the two ions could be generated to observe the sidebands. Several years ago, while evaluating suspended trapping pulse sequences for alleviating space charge in the gas chromatography experiment [21], we observed that FTICR spectra of large methylnaphthalene ion populations were far more susceptible to space-charge distortion than equivalent populations of similar molecules. The only distinguishing characteristic of methylnaphthalene was the presence of two closely spaced ions in the EI spectrum.…”
mentioning
confidence: 99%
“…Another approach to reduce the space-charge effect on mass accuracy is to regulate the ion population in the cell by using a suspended trapping procedure (Laude & Beu, 1989;Hogan & Laude, 1990). This technique is based upon suspending the trapplate potentials for a few milliseconds and allowing some ions trapped in the cell to escape.…”
Section: A External Mass Calibrationmentioning
confidence: 99%
“…This technique is based upon suspending the trapplate potentials for a few milliseconds and allowing some ions trapped in the cell to escape. When this procedure is employed, an accurate mass calibration can be achieved independent of initial ion population in the trapped ion cell (Laude & Beu, 1989;Hogan & Laude, 1990). Laude and co-workers (Laude & Beu, 1989;Hogan & Laude, 1990) applied this method to GC/FTMS analysis, and they demonstrated that the shifts in cyclotron frequency over the eluting GC peak profile can be significantly reduced from 210 Hz to less than 3 Hz.…”
Section: A External Mass Calibrationmentioning
confidence: 99%