2007
DOI: 10.1016/j.aca.2007.02.072
|View full text |Cite
|
Sign up to set email alerts
|

Surface plasmon resonance sensor for lysozyme based on molecularly imprinted thin films

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

5
39
0
2

Year Published

2010
2010
2018
2018

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(48 citation statements)
references
References 31 publications
5
39
0
2
Order By: Relevance
“…Chen et al 163 also used a small amount of methacrylic acid as copolymer, alongside Nisopropylacrylamide as the major functional monomer, in order to synthesise hydrogels specific for lysozyme and cytochrome C. Matsunaga et al 203 similarly produced lysozyme-imprinted hydrogels films on a sensor surface using an acidic monomer, acrylic acid. In addition to the acidic monomer, the zwitterionic monomer, 2-methacryloylethyl phosphorylcholine, was included in their polymer composition in order to reduce non-specific binding to the hydrogels.…”
Section: Choice Of Functional Monomermentioning
confidence: 99%
See 2 more Smart Citations
“…Chen et al 163 also used a small amount of methacrylic acid as copolymer, alongside Nisopropylacrylamide as the major functional monomer, in order to synthesise hydrogels specific for lysozyme and cytochrome C. Matsunaga et al 203 similarly produced lysozyme-imprinted hydrogels films on a sensor surface using an acidic monomer, acrylic acid. In addition to the acidic monomer, the zwitterionic monomer, 2-methacryloylethyl phosphorylcholine, was included in their polymer composition in order to reduce non-specific binding to the hydrogels.…”
Section: Choice Of Functional Monomermentioning
confidence: 99%
“…121,[154][155][156]160,162,180,203 Surface-constrained templates, as required by contact imprinting 127,189,199 and surface confined epitope approaches 117 are probably the most readily adapted to incorporation with transducer surfaces. In these cases a planar thin film results from a casting process, polymer-forming components being confined as a thin film between surfaces, one treated to bind to the polymer (corresponding to the transducer surface) and the other, bearing the template structure, allowing easy release.…”
Section: Polymer Format For Sensing Applicationsmentioning
confidence: 99%
See 1 more Smart Citation
“…[15] Given the diversity of proteins in terms of physical chemical properties it is unlikely to have the full range of interactions for high affinity binding covered by these simple MIPs. Therefore, the success rate of this probabilistic approach was increased in many cases by focusing on proteins with distinctive properties [8,23] that facilitates the likelihood of obtaining binding sites with both strong and selective interaction with the target. However, for "random"…”
Section: Introductionmentioning
confidence: 99%
“…В качестве планарных поверхностей используют стекло, слюду, кремний. Метод поверхностного плазмонного резонанса (SPR) был применен для анализа лизоцима [33]. Золотой чип был модифицирован полимером на основе полиакриламида с использование лизоцима в качестве молекулы-шаблона.…”
Section: области применения мип для анализа белков электрохимическиеunclassified