2021
DOI: 10.1002/adfm.202106061
|View full text |Cite
|
Sign up to set email alerts
|

Superswelling Microneedle Arrays for Dermal Interstitial Fluid (Prote)Omics

Abstract: The noninvasive sampling of dermal interstitial fluid (ISF) for the monitoring of clinical biomarkers is a greatly appealing area of research. The identification of molecular biomarkers in biological fluids has been accelerated with ‐omics analyses but remains limited in ISF because of its time‐consuming and complex extraction process. Here, the generation of microneedle (MN) patches made of superabsorbent acrylate‐based hydrogels for the rapid sampling of dermal ISF is described to explore its proteome. In de… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
31
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(32 citation statements)
references
References 106 publications
1
31
0
Order By: Relevance
“…Recently, Zheng et al reported the collection of 13 μL of dermal ISF from the pig skin ex vivo in 20 min using MNs formulated with methacrylated hyaluronic acid and maltose. 41 Laszlo et al have designed superswelling acrylate-based MN arrays to rapidly collect 15 μL of dermal ISF in the excised pig skin in less than 1 h. 29 Chang et al have reported that 2.3 μL of ISF in the mouse in 10 min could be extracted by the cross-linked MeHA-MN patch. 42 He et al developed a point-of-care testing (POCT)platform based on hydrogel microneedle patches, which can extract 7.5 mg of skin ISF from the mimetic skin model.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recently, Zheng et al reported the collection of 13 μL of dermal ISF from the pig skin ex vivo in 20 min using MNs formulated with methacrylated hyaluronic acid and maltose. 41 Laszlo et al have designed superswelling acrylate-based MN arrays to rapidly collect 15 μL of dermal ISF in the excised pig skin in less than 1 h. 29 Chang et al have reported that 2.3 μL of ISF in the mouse in 10 min could be extracted by the cross-linked MeHA-MN patch. 42 He et al developed a point-of-care testing (POCT)platform based on hydrogel microneedle patches, which can extract 7.5 mg of skin ISF from the mimetic skin model.…”
Section: ■ Results and Discussionmentioning
confidence: 99%
“…Microneedles (MNs) that consist of an array of dozens of needles with a height of 50–1500 μm, a tip diameter of 1–100 μm, and a bottom width of 25–500 μm, can effectively avoid the stimulation of dermal nerve endings for pain-free delivery. Recently, MNs-based transdermal delivery has been designed for various biomedical applications such as the treatment of neuropathic pain, eye diseases, hair regrowth, , obesity, , diabetes mellitus, cancer, influenza vaccination research, and contraception . However, little effort has been devoted to the MNs-related ISF diagnosis, which was mainly limited by the unsatisfied sampling capacity, sampling kinetics, as well as the low abundance of biomarkers in the ISF. A MNs-based platform for the longitudinal sampling of cells and ISF was developed with the limitation on detecting targets with high natural abundance in the skin ISF . Sulaiman et al have first reported an MNs detection system for sampling and detecting specific nucleic acid biomarkers from ISF, and the reports were accomplished on human skin ex vivo models for the low swelling rate of MNs .…”
mentioning
confidence: 99%
“…[27] In addition, ISF was non-coagulable and had the potential to achieve continuous monitoring. [28] Omic analysis could identify biomarkers, Elise et al [29] designed the MNs made of superabsorbent acrylate-based hydrogel and used them for ISF sampling to explore the proteome. After proteomic analysis, the researchers detected 176 clinically relevant biomarkers in the collected samples, indicating the potential of ISF as an important source of biomarkers for disease monitoring and diagnosis.…”
Section: The Composition Of Isfmentioning
confidence: 99%
“…The developed GelMA MN patch exhibits an efficient extraction of ISF. Laszlo et al (2021) proposed two hydrogel-based MN arrays for dermal ISF proteomics sampling. The developed MN patches could restore their initial shape even after multiple mandatory washing steps to erase un-crosslinked polymers.…”
Section: Microneedles For Transdermal Samplingmentioning
confidence: 99%