2006
DOI: 10.1080/00365510600902362
|View full text |Cite
|
Sign up to set email alerts
|

Standardization of p‐creatinine assays and use of lean body mass allow improved prediction of calculated glomerular filtration rate in adults: A new equation

Abstract: A new creatinine-based equation derived in a mainly Caucasian patient sample is a better predictor of GFR than CG-type equations irrespective of the body weight measure used or, if bias-adjusted, when using zero-calibrated creatinine assays.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
23
0
1

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(25 citation statements)
references
References 40 publications
1
23
0
1
Order By: Relevance
“…Serum and urine albumin, IgG, and urine protein HC were determined by immunoturbidimetry using a Cobas Mira S system (Roche Inc.) and monospecific rabbit antisera obtained from Dako (Copenhagen, Denmark) [13][14][15]. GFR was estimated using the Lund-Malmö formula [16,17]: eGFR for patients with plasma creatinine (pCr) <150 µmol/L = e 4.62-0.0112*pCr-0.0124*age+0.339*ln(age)-0.2226(if female) .…”
Section: Laboratory Analysismentioning
confidence: 99%
“…Serum and urine albumin, IgG, and urine protein HC were determined by immunoturbidimetry using a Cobas Mira S system (Roche Inc.) and monospecific rabbit antisera obtained from Dako (Copenhagen, Denmark) [13][14][15]. GFR was estimated using the Lund-Malmö formula [16,17]: eGFR for patients with plasma creatinine (pCr) <150 µmol/L = e 4.62-0.0112*pCr-0.0124*age+0.339*ln(age)-0.2226(if female) .…”
Section: Laboratory Analysismentioning
confidence: 99%
“…At a g-I/GFR ratio <1.0 the reported CIN frequency was <3% (Gurm et al, 2011;Laskey et al, 2007;Nyman et al, 2008 Total 5026…”
Section: Gram-iodine/egfr Ratiomentioning
confidence: 99%
“…Weighted mean value with individual study sizes as weights were finally calculated based on log-transformation of volume/eGFR and g-I/eGFR ratio. Absolute GFR was estimated in 3 reports (Laskey et al, 2007;Nyman et al, 2008;Worasuwannarak & Pornratanarangsi, 2010) and relative GFR in the remaining. 1.…”
Section: Gram-iodine/egfr Ratiomentioning
confidence: 99%
See 1 more Smart Citation
“…OmniVis equations use plasma (serum)-creatinine (P-crea) (expressed in μmol/L), age (in years), weight (kg), height (cm) and gender. Two equations can be calculated with OmniVis, the Lund-Malmö and the Cockcroft-Gault equations [44].…”
Section: Safetymentioning
confidence: 99%