Stability of the Light Output, Oral Cavity Tip Accessibility in Posterior Region and Emission Spectrum of Light-Curing Units

Abstract: Not all of the blue-emitting lights deliver the same emission spectra, and some curing lights delivered a lower irradiance (as much as 8% lower) after the 25th exposure.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
19
0
1

Year Published

2018
2018
2022
2022

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 29 publications
(20 citation statements)
references
References 29 publications
0
19
0
1
Order By: Relevance
“…Modern LED LCUs use 1-8 LEDs in an array which is flat [23], which makes bundling the light more difficult and may result in an inhomogeneous beam profile, despite being a mono-wavelength unit (peak at around 450-470 nm). Finally, the last step in development is the broad spectrum LED LCU, which uses different types of LEDs, emitting light with different wavelengths (violet light (380 -420 nm) and blue light (420 -495 nm) [8,20]. Therefore they are able to activate different types of photoinitiators [24].…”
Section: Original Articlementioning
confidence: 99%
See 1 more Smart Citation
“…Modern LED LCUs use 1-8 LEDs in an array which is flat [23], which makes bundling the light more difficult and may result in an inhomogeneous beam profile, despite being a mono-wavelength unit (peak at around 450-470 nm). Finally, the last step in development is the broad spectrum LED LCU, which uses different types of LEDs, emitting light with different wavelengths (violet light (380 -420 nm) and blue light (420 -495 nm) [8,20]. Therefore they are able to activate different types of photoinitiators [24].…”
Section: Original Articlementioning
confidence: 99%
“…Very large differences have been documented when comparing the light curing of untrained vs trained dentists [5]. Furthermore, the dentist should be aware that the irradiance of an LCU diminishes as the distance increases from the light output window [6] and, besides that, the cleanliness aspect of the LCU light tip is fundamental, because any residual RBC stuck onto the light exiting window may also reduce the light irradiance, which is a huge problem that affects the geometry of the light tip which may create shadows [7,8], and thus the depth of the cure may be reduced. Furthermore, depending on their composition (filler, resin mix, pigments and opacifiers), RBCs absorb more or less light [9], which reduces the depth of the cure as well.…”
Section: Introductionmentioning
confidence: 99%
“…However, different clinical situations can make this difficult or almost impossible, such as the restauration location and the light tip angulation versus patient mouth aperture ( Fig. 7) [17,18].…”
Section: Positioningmentioning
confidence: 99%
“…A handheld radiometer is designed to measure exitance irradiance of LCUs and not the radiant exposure received by the restoration (18,19) nor the LCU radiant power emitted. However, a new handheld dental radiometer was developed to measure both irradiance and radiant power of LCUs: Bluephase II (Ivoclar Vivadent, Schaan, Liechtenstein) (20).…”
Section: Introductionmentioning
confidence: 99%