2013
DOI: 10.1016/j.talanta.2013.05.031
|View full text |Cite
|
Sign up to set email alerts
|

Square-wave stripping voltammetric determination of caffeic acid on electrochemically reduced graphene oxide–Nafion composite film

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

4
40
1

Year Published

2014
2014
2018
2018

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 87 publications
(45 citation statements)
references
References 27 publications
4
40
1
Order By: Relevance
“…The observed plot indicated that the CA oxidation had a linearity with the linear regression equation of Ipa (μA) = 0.0889 × 10 −6  A/mVs −1  + 4.489 μA (R 2  = 0.9959) and Ipc (μA) = 0.0677 × 10 −6  A/mVs −1  − 3.396 μA (R 2  = 0.9957). This study indicated that the electrocatalytic oxidation of CA at NDC/GCE was controlled by the adsorption controlled process22.…”
Section: Resultsmentioning
confidence: 74%
See 1 more Smart Citation
“…The observed plot indicated that the CA oxidation had a linearity with the linear regression equation of Ipa (μA) = 0.0889 × 10 −6  A/mVs −1  + 4.489 μA (R 2  = 0.9959) and Ipc (μA) = 0.0677 × 10 −6  A/mVs −1  − 3.396 μA (R 2  = 0.9957). This study indicated that the electrocatalytic oxidation of CA at NDC/GCE was controlled by the adsorption controlled process22.…”
Section: Resultsmentioning
confidence: 74%
“…In addition, the lead modified GCE (PbFE-GCE), laccase-MWCNT and gold nanoparticles modified electrodes were reported for the electrochemical determination of CA181920. Recently, the chemically reduced and electrochemically reduced graphene oxide modified electrodes are investigated for the determination of CA which revealed a superior performance2122. Commonly, graphene or derivatives of graphene have been widely used in many different applications due to its remarkable physicochemical properties23.…”
mentioning
confidence: 99%
“…Taking the above mentioned lacune and the high electroactivity of PCM into consideration, electrochemical analytical techniques for PCM determination has been 3 widely explored method due to simplicity, high sensitivity, low cost, easy operation and possibility to miniaturization [18][19][20][21]. Hence, considerable efforts have been devoted to modify the electrode for enhancing its voltammetric response and analytical performance [23][24][25][26][27][28][29][30][31][32][33][34][35][36]. Another problem commonly encountered at bare electrode is that they get poisoned by several species and decrease sensitivity and reproducibility.…”
Section: Introductionmentioning
confidence: 99%
“…Moghaddam and coauthors [15] indicated that SWCNT with graphite-based electrode offered an improvement in the CA electrochemical behavior and investigated the influence of the scan rate in the CA oxidation by CV measurement. With the presence of CA, the anodic and cathodic peak was 17-fold higher than that of a bare GCE [16].…”
Section: Introductionmentioning
confidence: 86%