2018
DOI: 10.1016/j.jchromb.2018.05.017
|View full text |Cite
|
Sign up to set email alerts
|

Splitless hyphenation of SFC with MS by APCI, APPI, and ESI exemplified by steroids as model compounds

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

2
18
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 36 publications
(20 citation statements)
references
References 64 publications
2
18
0
Order By: Relevance
“…In the most recent publication, Parr et al . reported the analysis of 32 underivatised steroids with an analysis time of 21 min and LODs ranging from 1 to 50 ng/mL 18 . In comparison, our method is fast (5 min) with LODs less than 0.05 ng/mL for most of the steroids that we measured.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…In the most recent publication, Parr et al . reported the analysis of 32 underivatised steroids with an analysis time of 21 min and LODs ranging from 1 to 50 ng/mL 18 . In comparison, our method is fast (5 min) with LODs less than 0.05 ng/mL for most of the steroids that we measured.…”
Section: Resultsmentioning
confidence: 99%
“…UPSFC has been connected to ESI, APCI and atmospheric pressure photoionisation (APPI) as ionisation sources for MS detection 15 , 18 . Parr et al .…”
Section: Resultsmentioning
confidence: 99%
“…The recent introduction of modern and reliable UHPSFC-MS systems allowed to experimentally prove some of the potential benefits of SFC over LC. Indeed, as shown in [28,[47][48][49][50], excellent values for LODs and LOQs were met, with LOD values often down to below 1 ppb [28]. However, SFC-MS does not systematically provide a clear advantage over LC-MS in terms of sensitivity.…”
Section: Achievable Sensitivity In Sfc-ms Vs Lc-msmentioning
confidence: 99%
“…This means that users have the possibility to modify the mobile phase composition before entering MS detection, so that the ionization process can be enhanced, especially in ESI mode. Some authors have recently demonstrated how the addition of either small quantities of water or the use of additives/buffers in the make-up pump, increased the MS signals, thus improving sensitivity [28,48]. Using a wide range of endogenous steroids, the authors screened different buffers/additives in the make-up solvent, finding that either pure ammonium fluoride or ammonium fluoride mixed with formic acid in the solvent, can greatly improve ionization efficiency in ESI mode for steroids.…”
Section: Accepted Manuscriptmentioning
confidence: 99%
See 1 more Smart Citation