2016
DOI: 10.1063/1.4959274
|View full text |Cite
|
Sign up to set email alerts
|

Spectroscopic imaging of limiter heat and particle fluxes and the resulting impurity sources during Wendelstein 7-X startup plasmas

Abstract: A combined IR and visible camera system [G. A. Wurden et al., "A high resolution IR/visible imaging system for the W7-X limiter," Rev. Sci. Instrum. (these proceedings)] and a filterscope system [R. J. Colchin et al., Rev. Sci. Instrum. 74, 2068 (2003)] were implemented together to obtain spectroscopic data of limiter and first wall recycling and impurity sources during Wendelstein 7-X startup plasmas. Both systems together provided excellent temporal and spatial spectroscopic resolution of limiter 3. Narrowba… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
22
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
7

Relationship

5
2

Authors

Journals

citations
Cited by 19 publications
(23 citation statements)
references
References 5 publications
1
22
0
Order By: Relevance
“…The effect of a perturbing n = 1 EX/P5-5 trim coil field on the limiter temperatures was examined. In figure 1 a stereotypical limiter IR camera image is shown [6,7]. Three lines are drawn across the limiter from which temperature data is extracted.…”
Section: Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…The effect of a perturbing n = 1 EX/P5-5 trim coil field on the limiter temperatures was examined. In figure 1 a stereotypical limiter IR camera image is shown [6,7]. Three lines are drawn across the limiter from which temperature data is extracted.…”
Section: Measurementsmentioning
confidence: 99%
“…The effect of error fields on limiter heat loads were also explored with the trim coils. A high resolution infrared camera [6,7] gave detailed imagery of the limiters during the pulse. Low limiter temperatures limited the range of diagnostic coverage during this first campaign.…”
Section: Introductionmentioning
confidence: 99%
“…The filtered visible camera provided absolutely calibrated measurements of carbon and hydrogen light, and therefore inputs to particle balance calculations. 22 The infrared camera was used to derive space and time resolved power fluxes, as well as in a calorimeter mode to infer total energy deposited on the limiter. measurements of limiter temperatures, heat flux density has been derived with the help of the THEODOR code.…”
Section: Diagnostics For Plasma Edge and In-vessel Componentsmentioning
confidence: 99%
“…10). The versatile gas injection system has been used for injection of helium for measurement of local edge n e and T e profiles 28 and effective particle confinement time τ p * He , 22 neon for development of a collisional radiative model to extend the parameter range and accuracy of the diagnostic helium beam, 28,29 argon for impurity transport studies as well as nitrogen for radiative edge cooling. Perpendicular observation of the gas emission at the upper plasma edge was done along 8 los, using quartz fibers and an imaging spectrometer with a CCD camera.…”
Section: Diagnostics For Plasma Edge and In-vessel Componentsmentioning
confidence: 99%
“…W7-AS [4,5], W7-X [6,7], LHD [8,9], HSX [10,11]) and tokamaks (e.g. DIII-D [12,13], NSTX [14,15], TEXTOR-DED [16,17]), yet their interpretation in terms of local quantities can be challenging due to line of sight integration effects.…”
Section: Introductionmentioning
confidence: 99%