2016
DOI: 10.1063/1.4964376
|View full text |Cite
|
Sign up to set email alerts
|

Overview of diagnostic performance and results for the first operation phase in Wendelstein 7-X (invited)

Abstract: Wendelstein 7-X, a superconducting optimized stellarator built in Greifswald/Germany, started its first plasmas with the last closed flux surface (LCFS) defined by 5 uncooled graphite limiters in December 2015. At the end of the 10 weeks long experimental campaign (OP1.1) more than 20 independent diagnostic systems were in operation, allowing detailed studies of many interesting plasma phenomena. For example, fast neutral gas manometers supported by video cameras (including one fast-frame camera with frame rat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
45
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 47 publications
(45 citation statements)
references
References 34 publications
0
45
0
Order By: Relevance
“…It has already been showed in TEXTOR that this new model gives better agreement with other diagnostics than the old model. 5 Comparisons with other edge diagnostics at W7-X are now being conducted, in particular with the Langmuir probes in the limiter 6,7 and at the multi-purpose fast manipulator 3,7 installed during the first operation phase.…”
Section: Resultsmentioning
confidence: 99%
“…It has already been showed in TEXTOR that this new model gives better agreement with other diagnostics than the old model. 5 Comparisons with other edge diagnostics at W7-X are now being conducted, in particular with the Langmuir probes in the limiter 6,7 and at the multi-purpose fast manipulator 3,7 installed during the first operation phase.…”
Section: Resultsmentioning
confidence: 99%
“…In addition to a set of low resolution near-IR cameras [7], we had a 3-5 µm band infrared (FLIR SC8303HD) camera (125 Hz full-frame rate, 1344 × 768 pixels) and a 400-800 nm AVT Prosilica GX-1050C (100 Hz full-frame rate, 1024 × 1024 pixels) color visible camera co-located on the same line of sight in Module 3 [8]. Additionally, an 8-14 µm DIAS IR camera (50 Hz, 640 × 480 pixels) viewed one side of Limiter 5 [9].…”
Section: Methodsmentioning
confidence: 99%
“…Using a combination of measurements from diamagnetic loops, TS, XICS, and other profile diagnostics, the energy confinement time is estimated at τE0.10 s. At our present understanding of the consistency and calibration accuracy of the diagnostics, the absolute value of τ E is believed to be accurately 20%, whereas relative changes in τ E can be detected down to 5%–10%, in particular, with the diamagnetic loops. An overview of the various diagnostics in operation in OP1.1 is presented elsewhere 20 . The triple product achieved was 0.8×1019 m –3  keV s for this 1.3 s discharge.…”
Section: Achieved and Predicted Triple Products For W7-xmentioning
confidence: 96%