2009
DOI: 10.1109/tap.2009.2028498
|View full text |Cite
|
Sign up to set email alerts
|

Specific Absorption Rate and Current Densities in the Human Eye and Head Induced by the Telemetry Link of an Epiretinal Prosthesis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
5
2
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(14 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…These interfaces can cause parts of the body, for example the eye, to resonate where the electric fields are increased and do not decay with distance. The SAR in the eye can be particularly high at frequencies between 600 and 2400MHz depending on the size of the eye, the surrounding tissues, the presence of the eyelid, the angle of incidence and the polarization as the eye is not perfectly spherical [8,[14][15].…”
Section: Sar Simulations and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…These interfaces can cause parts of the body, for example the eye, to resonate where the electric fields are increased and do not decay with distance. The SAR in the eye can be particularly high at frequencies between 600 and 2400MHz depending on the size of the eye, the surrounding tissues, the presence of the eyelid, the angle of incidence and the polarization as the eye is not perfectly spherical [8,[14][15].…”
Section: Sar Simulations and Analysismentioning
confidence: 99%
“…The eyes have received particular attention in the literature [8,[14][15]. As the metallic shape of the glasses extends around the front of the eye, it is important to use the anatomical head model which includes an eye -this can only be evaluated via simulations.…”
Section: Sar Simulations and Analysismentioning
confidence: 99%
“…Employing lowfrequency carriers is also supported by recent SAR calculations, e.g. in the telemetry link of an epiretinal prosthesis reported in (Singh et al, 2009), the SAR limit of the IEEE standard would be crossed around 16 MHz for a normalized peak current of 0.62 A in the primary coil. Thus, for power transmission, carrier frequencies of inductive links are typically chosen below 15 MHz (Jow & Ghovanloo, 2007Simard et al, 2010).…”
Section: Inductive Linksmentioning
confidence: 77%
“…Whittow used a ring‐type jewellery near the region of the eye, and the downside is the medium is purely homogeneous, and dipole the most basic antenna is used for analysis. Singh et al estimated SAR for patients with epiretinal Prosthesis. The cases of this system are rare in implementation.…”
Section: Exposure Areasmentioning
confidence: 99%