2019 41st Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 2019
DOI: 10.1109/embc.2019.8856540
|View full text |Cite
|
Sign up to set email alerts
|

Smartphone PPG: signal processing, quality assessment, and impact on HRV parameters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
2
2
1
1

Relationship

2
4

Authors

Journals

citations
Cited by 14 publications
(11 citation statements)
references
References 15 publications
0
10
0
Order By: Relevance
“…Data acquisition RR-interval sequences from 1,471 subjects were obtained through the Welltory app, which subjects used to take heart rate variability measurements with their smartphone cameras or Apple Watch while in a resting state, after completing a stress self-assessment questionnaire (Perceived Stress Questionnaire (PSQ)) on the same day. We excluded measurements that showed possible arrhythmias in research subjects [23] , as well as low-quality measurements [24] , because these factors can significantly distort HRV metrics. The RR-interval sequences were used to calculate AMo, pNN50, and MedSD values.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Data acquisition RR-interval sequences from 1,471 subjects were obtained through the Welltory app, which subjects used to take heart rate variability measurements with their smartphone cameras or Apple Watch while in a resting state, after completing a stress self-assessment questionnaire (Perceived Stress Questionnaire (PSQ)) on the same day. We excluded measurements that showed possible arrhythmias in research subjects [23] , as well as low-quality measurements [24] , because these factors can significantly distort HRV metrics. The RR-interval sequences were used to calculate AMo, pNN50, and MedSD values.…”
Section: Methodsmentioning
confidence: 99%
“…4. The quality of the heart rate variability measurements taken by participants was high enough (measurement quality is calculated based on data obtained from the measurement device [24] ).…”
Section: Methodsmentioning
confidence: 99%
“…Using the phones cameras as a PPG sensors has also been thoroughly investigated in the literature. A popular approach leverages the PPG technique to monitor heart activity when a user places the finger on the smartphone camera [6], [7], [47]- [53], similar to the principle of oximeters. However, such approaches require active user participation and their accuracy depends on multiple factors, including precise finger placement with respect to the camera [7].…”
Section: Related Workmentioning
confidence: 99%
“…However, such models are accessible only to a limited number of users. To relax the requirement for custom hardware or high-end phones with special sensors, [6], [7] introduced solutions that use a standard smartphone camera to measure heart rate using the PPG technique. However, users are required to place the finger on the camera, with the accuracy tightly coupled to the precise placement [7].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation