Order By: Relevance
“…The concentration of 2-methylcyclopentanone was calculated in ppm using the following equation. 47 where C is the vapor concentration required, ρ is the density of the liquid (g mL –1 ), T is the temperature (K), V s is the volume of the liquid analyte (μL), M is the molecular weight of the liquid analyte (g mol –1 ), and V is the volume of the test chamber (L). All experiments were carried out at room temperature.…”
Section: Methodsmentioning
confidence: 99%
“…The concentration of 2-methylcyclopentanone was calculated in ppm using the following equation. 47 where C is the vapor concentration required, ρ is the density of the liquid (g mL –1 ), T is the temperature (K), V s is the volume of the liquid analyte (μL), M is the molecular weight of the liquid analyte (g mol –1 ), and V is the volume of the test chamber (L). All experiments were carried out at room temperature.…”
Section: Methodsmentioning
confidence: 99%
“…Recently more and more peripherals have begun using Bluetooth to wirelessly transmit data to and from the smartphone, as seen in the examples in Figure . The obvious benefit is that these types of peripherals are compatible with all types of smartphones regardless of the make or model.…”
Section: Integration With Smartphonementioning
confidence: 99%
“…Hence, most of the PoC oriented EIS sensors require power sources such as a 9 V lithium ion battery. As is true with the other two measurement modes, there exists a popular commercial IC solution, AD5933 , which is able to fit a complete digital signal generator (DDS) core, DAC, ADC, and discrete Fourier transform (DFT) hardware into a single small chip as is shown in Figure (A) . However, the main issues with this IC are that the smallest potential stimulus it can apply is ∼200 mV peak‐to‐peak and the bias point cannot be set independently of the amplitude.…”
Section: Poc Implementations Of E‐chem Techniquesmentioning
confidence: 99%
“…The merits of smartphones brought new possibilities for biomedical and biosensor research. Recently, many studies on smartphone-controlled platforms at the point of care (POC) have been published and several electrochemical methods have been combined with smartphone for quantitative electrochemical detections, such as chronoamperometry (CA), cyclic voltammetry (CV), differential pulse voltammetry (DPV) [13,14] and electrochemical impedance spectroscopy (EIS) [14][15][16][17]. Among them, DPV is capable of detection of low-level concentrations of analytes.…”
Section: Introductionmentioning
confidence: 99%