2014
DOI: 10.1109/tste.2014.2312328
|View full text |Cite
|
Sign up to set email alerts
|

Sizing of Energy Storage and Diesel Generators in an Isolated Microgrid Using Discrete Fourier Transform (DFT)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
99
0
2

Year Published

2016
2016
2021
2021

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 183 publications
(102 citation statements)
references
References 17 publications
0
99
0
2
Order By: Relevance
“…Formulated optimization problem has the form: The balance power P B of the studied microgrid should satisfy the following equations (see Ref. [6]):…”
Section: Economic Scheduling Optimization Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…Formulated optimization problem has the form: The balance power P B of the studied microgrid should satisfy the following equations (see Ref. [6]):…”
Section: Economic Scheduling Optimization Modelmentioning
confidence: 99%
“…In Ref. [6] is stated, that the high speed (3,600 r/min), air-cooled diesel can be used for about 20,000…”
Section: Economic Scheduling Optimization Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…A small power system consisting of power converter-based generation, ES devices, small classic synchronous generation, and various types of loads forms a microgrid (MG) [4]. While a number of research works on MG have been done on various aspects, including control strategy [5][6][7][8][9][10], energy management systems [11][12][13][14][15][16][17], marketing policies [18][19][20][21] and system design [22][23][24][25][26][27], this paper mainly focuses on the optimal sizing of Distributed Energy Resources (DERs), especially the capacity of ES devices in MG.…”
Section: Introductionmentioning
confidence: 99%
“…The case illustrated in that work adopts hour-level data and emphasized the influence on optimization result caused by variation of diesel generation capacities. The authors of [27] propose a method for coordinated sizing of energy storage (ES) and diesel generators in an isolated microgrid based on discrete Fourier transform. The power fluctuation is decomposed into high-frequency component and low-frequency component, then ES and diesel generators are assigned to these two parts of power correspondingly for power smoothing according to their respond characteristics.…”
Section: Introductionmentioning
confidence: 99%