2020
DOI: 10.1016/j.ijepes.2020.105935
|View full text |Cite
|
Sign up to set email alerts
|

Site experimental study on suspension-tension arrangement for preventing transmission lines from icing tripping

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
8
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 11 publications
(8 citation statements)
references
References 12 publications
0
8
0
Order By: Relevance
“…However, some cases may demand that insulators are installed in other orientations and therefore designed for optimum performance at such orientation angles. A typical example is the strain insulator configuration (suspensiontension type) which is designed to support extraordinary and irregular line conductor tensile loads, such as in sharp corners and dead ends whilst enhancing the flashover voltage of the same length of insulator string when contaminated [24,25]. This study investigated the need for a modified insulator design in accordance with the angle of installation.…”
Section: F Orientation Angle Testmentioning
confidence: 99%
“…However, some cases may demand that insulators are installed in other orientations and therefore designed for optimum performance at such orientation angles. A typical example is the strain insulator configuration (suspensiontension type) which is designed to support extraordinary and irregular line conductor tensile loads, such as in sharp corners and dead ends whilst enhancing the flashover voltage of the same length of insulator string when contaminated [24,25]. This study investigated the need for a modified insulator design in accordance with the angle of installation.…”
Section: F Orientation Angle Testmentioning
confidence: 99%
“…where r0 is the arc radius. The arc radius increases with the decreasing air pressure, which can be expressed as follows [29]   (8) where P is the pressure at high altitude and P0 is the standard atmospheric pressure.…”
Section: B Flashover Process Of the Insulators Covered With Natural mentioning
confidence: 99%
“…A systematic investigation on ice-covered insulators have been carried out and achieved important advances in the formation mechanism of ice accretion [5]- [7], electrical properties [8]- [10] and discharge development [11]- [12]. However, less attention has been paid to the effect of snow accumulation on the external insulation of transmission lines.…”
Section: Introductionmentioning
confidence: 99%
“…It measures physical parameters such as line tension, dip, swing angle, and micro-meteorological parameters such as temperature, humidity, wind speed by sensors. Then in the background software of the master station, the equivalent ice thickness is calculated combined with the mechanical model to determine the icing status [9][10][11]. Zhao et al [12] developed an automatic icing warning system that calculated the thickness utilising stress measurement.…”
Section: Introductionmentioning
confidence: 99%
“…the master station, the equivalent ice thickness is calculated combined with the mechanical model to determine the icing status [9][10][11]. Zhao et al [12] developed an automatic icing warning system that calculated the thickness utilising stress measurement.…”
mentioning