2005
DOI: 10.1016/j.aca.2004.10.035
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous kinetic determination of Fe(II) and Fe(III) based on their reactions with NQT4S in micellar media by using PLS and PCR methods

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
11
0

Year Published

2006
2006
2019
2019

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 17 publications
(11 citation statements)
references
References 34 publications
0
11
0
Order By: Relevance
“…Interested readers can refer to references [22][23][24][25][26][27][28][29][30] for its further information. As two full spectrum multivariate calibration methods, PLS and principal component regression (PCR) only need to know the concentration of the analyte of interest in the calibration samples and it is unnecessary to know the concentration of other analytes.…”
Section: Introductionmentioning
confidence: 99%
“…Interested readers can refer to references [22][23][24][25][26][27][28][29][30] for its further information. As two full spectrum multivariate calibration methods, PLS and principal component regression (PCR) only need to know the concentration of the analyte of interest in the calibration samples and it is unnecessary to know the concentration of other analytes.…”
Section: Introductionmentioning
confidence: 99%
“…Alloy samples [74] Cr and Co The difference of their catalytic effect in luminolhydrogen peroxide chemiluminescence reaction 0-10 μg ml -1 Water samples [75] Widely used to obtain multivariate regression models, several publications on the application of PLSR for simultaneous kinetic analysis are listed in Table 2 [82,[86][87][88][89][90][91][92][93][94][95][96][97].…”
Section: Partial Least Squares Regressionmentioning
confidence: 99%
“…The difference observed in the rates of the complex formation of iron in its two oxidation states with 1,2-naphthaquinone-2-thiosemicarbazone-4-sulphonic acid (NQT4S) at pH 4.0 in cetyltrimethylammoniumbromide (CTAB) as micellar media, respectively 0.10-2.10 g ml -1 for Fe(II) and 0.25-2.25 g ml -1 for Fe(III) Environmental samples [89] Carbidopa, levodopa and methyldopa…”
Section: Partial Least Squares Regressionmentioning
confidence: 99%
“…Besides, the other techniques http://dx.doi.org/10.1016/j.saa.2014. 11.071 1386-1425/Ó 2014 Elsevier B.V. All rights reserved. applied in Fe speciation, e.g.…”
Section: Introductionmentioning
confidence: 98%
“…UV/Vis spectrophotometry [1][2][3][4][5][6][7][8][9][10][11] is the most common analytical method applied to Fe speciation. Besides, the other techniques http://dx.doi.org/10.1016/j.saa.2014.…”
Section: Introductionmentioning
confidence: 99%