2010
DOI: 10.1016/j.jhazmat.2009.10.092
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous spectrophotometric determination of trace amount of malachite green and crystal violet in water after cloud point extraction using partial least squares regression

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
52
1

Year Published

2013
2013
2024
2024

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 115 publications
(56 citation statements)
references
References 33 publications
2
52
1
Order By: Relevance
“…Over the years, an increasing number of analytical techniques such as spectrophotometry [6][7][8], high performance liquid chromatography (HPLC) [9][10][11], capillary electrophoresis Raman spectroscopy (CE-RS) [12], liquid chromatography tandem mass spectrometry (LC/MS n ) [2,13,14] and RNA-Aptamer-based assay [15] have been adapted for the detection of MG in various water matrices. Although the aforementioned techniques are considered as routine MG detection techniques, they are time-consuming and require complicated sample pretreatment (e.g., extraction, pre-concentration, derivatization, etc.).…”
Section: Introductionmentioning
confidence: 99%
“…Over the years, an increasing number of analytical techniques such as spectrophotometry [6][7][8], high performance liquid chromatography (HPLC) [9][10][11], capillary electrophoresis Raman spectroscopy (CE-RS) [12], liquid chromatography tandem mass spectrometry (LC/MS n ) [2,13,14] and RNA-Aptamer-based assay [15] have been adapted for the detection of MG in various water matrices. Although the aforementioned techniques are considered as routine MG detection techniques, they are time-consuming and require complicated sample pretreatment (e.g., extraction, pre-concentration, derivatization, etc.).…”
Section: Introductionmentioning
confidence: 99%
“…Frequently, the multivariate calibration methods like partial least squares (PLS) (Martens and Naes 1989;Geladi and Kowalski 1986) have been applied to mixtures without resorting to time-consuming chemical separation like chromatography. PLS has been successfully used for the simultaneous determination of pollutants in water and environmental samples (Gholivand et al 2012;An et al 2010;Gao et al 2011;Sarnacchiaro et al 2012).…”
Section: -N (Environmental Protection Agency 1991) the Nationalmentioning
confidence: 99%
“…Over the years, an increasing number of analytical techniques such as spectrophotometry [6,7,8], high performance liquid chromatography (HPLC) [9,10,11], capillary electrophoresis Raman spectroscopy (CE-RS) [12], liquid chromatography tandem mass spectrometry (LC/MS n ) [2,13,14] and RNA-Aptamer–based assay [15] have been adapted for the detection of MG in various water matrices. Although the aforementioned techniques are considered as routine MG detection techniques, they are time-consuming and require complicated sample pretreatment (e.g., extraction, pre-concentration, derivatization, etc.).…”
Section: Introductionmentioning
confidence: 99%