2008
DOI: 10.2116/analsci.24.1589
|View full text |Cite
|
Sign up to set email alerts
|

Simultaneous Determination of Creatinine and Uric Acid in Human Urine by High-Performance Liquid Chromatography

Abstract: An environmentally friendly reversed-phase HPLC method for simultaneous determination of creatinine and uric acid in human urine samples has been developed. Human urine samples were pretreated by dilution, protein precipitation, centrifugation and filtration, followed by HPLC separations using a reversed-phase C18 column with an aqueous mobile phase of phosphate buffer. The retention loss of a C18 column when using the highly aqueous mobile phases was avoided by employing a gradient elution using a small volum… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
51
0
1

Year Published

2009
2009
2018
2018

Publication Types

Select...
9
1

Relationship

0
10

Authors

Journals

citations
Cited by 92 publications
(53 citation statements)
references
References 27 publications
(36 reference statements)
1
51
0
1
Order By: Relevance
“…So far only a few methods covering some of the above mentioned analytes in urine were described. For example Zuo et al described a HPLC-UV method for CREA and UA, while Shirao et al analyzed CREA, HVA and UA using miscellar electrokinetic chromatography [17,18]. Antunes et al validated a HPLC-UV method for CREA and UA in dried urine spots [11].…”
Section: Tablementioning
confidence: 99%
“…So far only a few methods covering some of the above mentioned analytes in urine were described. For example Zuo et al described a HPLC-UV method for CREA and UA, while Shirao et al analyzed CREA, HVA and UA using miscellar electrokinetic chromatography [17,18]. Antunes et al validated a HPLC-UV method for CREA and UA in dried urine spots [11].…”
Section: Tablementioning
confidence: 99%
“…9,10 Using a spectrophotometer, the UA content was determined by its ability to reduce Fe (III) to Fe (II), which can then coordinate with phenanthroline to produce orangered complexes. 11 …”
Section: Tem Detection Of Urinary Crystallitesmentioning
confidence: 99%
“…Zuo et al 12 developed an environmentally friendly reversed-phase HPLC method for simultaneous determination of creatinine and UA in human urine samples, which were pretreated by dilution, protein precipitation, centrifugation and filtration, followed by HPLC separations using a reversed-phase C18 column with an aqueous mobile phase of phosphate buffer. This developed method provided a simple, rapid separation and sensitive detection for the species of interest in 10 min with UV detection at 205 nm.…”
Section: Hplc Methodmentioning
confidence: 99%