2009
DOI: 10.1109/tie.2008.2010175
|View full text |Cite
|
Sign up to set email alerts
|

Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter

Abstract: Abstract-An accurate small signal model of three phase photovoltaic inverters with a high order grid filter is derived in this paper. The proposed model takes into account the influence of both the inverter operating point and the PV panels characteristics on the inverter dynamic response. A sensitivity study of the control loops to variations of the dc voltage, the PV panels transconductance, the supplied power, and the grid inductance is performed using the proposed small-signal model. Analytical and experim… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
107
0
11

Year Published

2011
2011
2018
2018

Publication Types

Select...
7
3

Relationship

0
10

Authors

Journals

citations
Cited by 244 publications
(125 citation statements)
references
References 32 publications
0
107
0
11
Order By: Relevance
“…Because of little affection of output power of PV generation on harmonic current, separate model of fundamental current and harmonic current could represent the real working condition. The harmonic current of PV generation is relevant to :Topology of PV inverter [5];Switching frequency and control algorithm of PV inverter [6];Output filter of PV generation [7];Harmonic impedance of grid [8];…”
Section: Photovoltaic Generation System Modelingmentioning
confidence: 99%
“…Because of little affection of output power of PV generation on harmonic current, separate model of fundamental current and harmonic current could represent the real working condition. The harmonic current of PV generation is relevant to :Topology of PV inverter [5];Switching frequency and control algorithm of PV inverter [6];Output filter of PV generation [7];Harmonic impedance of grid [8];…”
Section: Photovoltaic Generation System Modelingmentioning
confidence: 99%
“…Typical converter configurations containing a GCC include: 1) a dc/dc/ac converter for solar, battery and fuel cell applications (Figueres et al, 2009;Wang and Nehrir, 2007), 2) a dc/ac converter for STATCOM applications (Luo et al, 2009;Carrasco et al, 2006), and 3) an ac/dc/ac converter for wind power and HVDC applications (Carrasco et al, 2006;Xu and Wang, 2007;Mullane et al, 2005;Pena et al, 1996;Rabelo et al, 2009).…”
Section: Introductionmentioning
confidence: 99%
“…The LCL filter design is implemented as per [18] to interface the inverter to the AC bus. In the steady state, the controlled three-phase AC bus current is i 2abc and voltage is v abc .…”
Section: Modeling Of Three-phase Inverter With Lcl Filtermentioning
confidence: 99%