2006
DOI: 10.1016/j.chroma.2006.04.014
|View full text |Cite
|
Sign up to set email alerts
|

Sensitive gas chromatographic–mass spectrometric method for the determination of phthalate esters, alkylphenols, bisphenol A and their chlorinated derivatives in wastewater samples

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
56
1
1

Year Published

2008
2008
2022
2022

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 113 publications
(60 citation statements)
references
References 25 publications
2
56
1
1
Order By: Relevance
“…4c and 5d); the MS fragmentation peaks characteristic of the BPA (357 and 372 m/z) were identical to those reported by other authors using similar experimental conditions Fig. 3 Ranges of the physico-chemical parameters measured in each of the sampling sites (S1 to S8) of the Mondego River estuary Environ Monit Assess (Ballesteros et al 2006;Silveira 2007). The analysis of the current data suggested that this pollutant was dumped in this estuary at or before the S8 sampling point by an occasional and/or deliberate discharge of a yet unknown industrial origin.…”
Section: Resultssupporting
confidence: 63%
See 1 more Smart Citation
“…4c and 5d); the MS fragmentation peaks characteristic of the BPA (357 and 372 m/z) were identical to those reported by other authors using similar experimental conditions Fig. 3 Ranges of the physico-chemical parameters measured in each of the sampling sites (S1 to S8) of the Mondego River estuary Environ Monit Assess (Ballesteros et al 2006;Silveira 2007). The analysis of the current data suggested that this pollutant was dumped in this estuary at or before the S8 sampling point by an occasional and/or deliberate discharge of a yet unknown industrial origin.…”
Section: Resultssupporting
confidence: 63%
“…The gas chromatographic system consisted in a Varian CP 3800 apparatus equipped with a VF-5ms type capillary column (30m×0.25 mm i.d., df: 0.25 μm) connected to an ion trap mass spectrometer (Varian Saturn 2200). The GC-MS analytical procedure used for the current estuarine water samples was based in several published protocols (Lee et al 2004;Ballesteros et al 2006;Shareef et al 2006) and was adjusted to the current samples accordingly to Silveira (2007). Thus, as the majority of the EDCs analysed (Fig.…”
Section: Chromatographic System and Main Methodological Characteristicsmentioning
confidence: 99%
“…The removal efficiency could be attributed to the sedimentation of solids and in the activated sludge which was not investigated. The level of phthalates detectable in the raw and effluent are higher than in other studies [20,21,23,24,25]. Throughout the three days sampling period, DEP concentration was higher than other phthalates investigated in the treatment plant.…”
Section: Occurrence and Removal Of Phthalates In The Wastewater Treatcontrasting
confidence: 59%
“…Several methods have been developed to assess the content of polyphenols in foods and beverages including chromatographic methods [10,11], capillary electrophoresis [12], spectrophotometry [13] and electrochemical methods [14,15].…”
Section: Introductionmentioning
confidence: 99%