1995
DOI: 10.1016/0021-9673(95)00262-l
|View full text |Cite
|
Sign up to set email alerts
|

Selectivity enhancement on a poly(butadiene-maleic acid)-coated cation phase induced by ethylene oxide-based complexing agents

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
10
0

Year Published

1999
1999
2017
2017

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 33 publications
(10 citation statements)
references
References 2 publications
0
10
0
Order By: Relevance
“…The chelation contribution is strongly depending on sample pH. As with many polymer-coated silica columns, manufacturing is not very reproducible, so eluant composition has to be optimized depending on the various column lots [26,27]. This stability problem was solved by the development of a polymer-based cation exchanger, which is traded as IonPac CS12 [28].…”
Section: Polymer-based Cation Exchangersmentioning
confidence: 99%
“…The chelation contribution is strongly depending on sample pH. As with many polymer-coated silica columns, manufacturing is not very reproducible, so eluant composition has to be optimized depending on the various column lots [26,27]. This stability problem was solved by the development of a polymer-based cation exchanger, which is traded as IonPac CS12 [28].…”
Section: Polymer-based Cation Exchangersmentioning
confidence: 99%
“…The addition of crown ethers (18-crown-6 and 15-crown-5) to acidic eluents in non-suppressed IC with conductimetric detection with columns packed with carboxylated silica and styrene-divinylbenzene copolymer resin to improve the peak resolution between mono-and divalent cations has recently been reported. 9,10 Therefore, the effect of these crown ethers added to 1.5 mmol dm 23 oxalic acid eluent was investigated for the complete separation of mono-and divalent cations on the Zorbax BP-SIL column.…”
Section: Effect Of Crown Ethers On the Retention Behavior Of Monoand ...mentioning
confidence: 99%
“…It has been reported that the addition of crown ethers, such as 1,4,7,10,13-pentaoxacyclopentadecane (15-crown-5) and 1,4,7,10,13,16-hexaoxacyclooctadecane (18-crown-6), to acidic eluents was very effective in improving the peak resolution between mono-and divalent cations on columns packed with carboxylated silica and styrene-divinylbenzene copolymer resin. 9,10 Therefore, the addition of these crown ethers to an acidic eluent was carried out in this work. Using a 1.5 mmol dm 23 oxalic acid-3 mmol dm 23 15-crown-5 as the eluent, both highly sensitive detection and excellent simultaneous separation of the mono-and divalent cations studied was achieved in 10 min.…”
mentioning
confidence: 99%
“…The addition of 18-crown-6 to an acidic eluent in IC-CD using carboxylated styrene-divinylbenzene co-polymer resin and carboxylated silica as the cation-exchange stationary phases is very effective for the improvement of peak resolution between these mono-and divalent cations [21,22]. Figure 3 shows the relationship between the concentration of 18-crown-6 in the eluent and the retention volumes of these mono-and divalent cations.…”
Section: Effect Of 18-crown-6 On Chromatographic Behavior Of Mono-andmentioning
confidence: 99%