2021
DOI: 10.1016/j.microc.2020.105798
|View full text |Cite
|
Sign up to set email alerts
|

Selective fluorometric determination of microcystin-LR using a segment template molecularly imprinted by polymer-capped carbon quantum dots

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
9
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(10 citation statements)
references
References 52 publications
0
9
0
Order By: Relevance
“…The obtained sensor presented a linear response of 1 to 1000 μg L –1 and a limit of detection (LOD) of 0.0093 μg L –1 of MC-LR. These novel materials were sensitive to MC-LR detection by fluorescence …”
Section: Molecularly Imprinted Polymers In Mcs Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The obtained sensor presented a linear response of 1 to 1000 μg L –1 and a limit of detection (LOD) of 0.0093 μg L –1 of MC-LR. These novel materials were sensitive to MC-LR detection by fluorescence …”
Section: Molecularly Imprinted Polymers In Mcs Analysismentioning
confidence: 99%
“…These novel materials were sensitive to MC-LR detection by fluorescence. 73 MIPs in conjunction with the Fabry−Peŕot interferometer have also been used to detect MC-LR in water. 192 Queiroś et al reported the synthesis of a Fabry−Peŕot sensor probe based on a fiber optic tip coated with a selective thin film of MC-LR.…”
Section: ■ Molecularly Imprinted Polymersmentioning
confidence: 99%
“…They used nonagrochemical trialkylmelamines as template molecules in place of atrazine, thus avoiding the troubles caused by analyte contaminants [ 30 ]. The authors proposed a fragment template docking molecular imprinting strategy for Microcystin-LR detection using L-leucine as the dummy template molecule [ 31 ].…”
Section: Introductionmentioning
confidence: 99%
“…For instance, there is no need for toxic solvents, expensive equipment, sophisticated sample preparation, and expert operators. 30,31 In spite of the vast effort, there is still a lack of accurate fluorometric sensors for many essential drugs. cence sensors have higher response stability and have been used widely for the detection of various drugs.…”
Section: Introductionmentioning
confidence: 99%
“…The fluorometric sensors based on CQDs have numerous advantages compared to the conventional detection methods such as Raman spectroscopy, electrophoresis, high-performance liquid chromatography (HPLC), and mass spectrometry. For instance, there is no need for toxic solvents, expensive equipment, sophisticated sample preparation, and expert operators. , In spite of the vast effort, there is still a lack of accurate fluorometric sensors for many essential drugs.…”
Section: Introductionmentioning
confidence: 99%