2021 IEEE Power &Amp; Energy Society Innovative Smart Grid Technologies Conference (ISGT) 2021
DOI: 10.1109/isgt49243.2021.9372177
|View full text |Cite
|
Sign up to set email alerts
|

Secondary Use-Plug-and-Play Energy Storage System Composed of Multiple Energy Storage Technologies

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
3
3

Relationship

2
4

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 5 publications
0
2
0
Order By: Relevance
“…These operations must be tightly synchronized and often autonomous to avoid errors and protect the energy infrastructure. This approach has been demonstrated in the development of energy storage systems and PV from residential [59], [60], [61], [62], to commercial-scale [63] systems in both hardware and controller hardware in the loop platforms. We note that other MQTT-based work for autonomous resource allocation systems was explored in [64] and for automation systems in [65].…”
Section: A Photovoltaic and Energy Storage System Architecturementioning
confidence: 99%
“…These operations must be tightly synchronized and often autonomous to avoid errors and protect the energy infrastructure. This approach has been demonstrated in the development of energy storage systems and PV from residential [59], [60], [61], [62], to commercial-scale [63] systems in both hardware and controller hardware in the loop platforms. We note that other MQTT-based work for autonomous resource allocation systems was explored in [64] and for automation systems in [65].…”
Section: A Photovoltaic and Energy Storage System Architecturementioning
confidence: 99%
“…In addition, if there is no isolation transformer but directly connected to the grid, it may inject DC current into the grid, causing magnetic saturation of transformers and electromagnetic components, and causing torque pulsation of nearby mechanical loads. At the present stage, there are still disadvantages such as huge manual access workload, low standardization, and difficulty in maintaining the association topology in the process of accessing the distribution IoT for massive local distributed renewable energy and smart meters and other end devices [7]. Meanwhile, when a large amount of distributed renewable energy is connected to the distribution system, it will largely affect the size and direction of the network tide, as well as the voltage of electrical components and customers [8].…”
Section: Introductionmentioning
confidence: 99%