2000
DOI: 10.1118/1.1287052
|View full text |Cite
|
Sign up to set email alerts
|

Scatter/primary in mammography: Monte Carlo validation

Abstract: The purpose of this investigation was to compare and validate the performance of the SIERRA Monte Carlo simulation routines for the analysis of the scatter to primary ratio (SPR) in the mammography setting. Two Monte Carlo simulation methods were addressed, the direct method was a straightforward and geometrically accurate simulation procedure, and the convolution method uses idealized geometry (monoenergetic, normally incident delta function input to the scattering medium) to produce scatter point spread func… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
92
0
1

Year Published

2006
2006
2019
2019

Publication Types

Select...
4
3
2

Relationship

1
8

Authors

Journals

citations
Cited by 101 publications
(98 citation statements)
references
References 17 publications
5
92
0
1
Order By: Relevance
“…The previously validated SIERRA Monte Carlo code system [8][9][10][11] was modified to accommodate the measurement geometry required in this investigation. Figure 1 illustrates the simulated acquisition geometry utilized.…”
Section: Iia Monte Carlo Simulationsmentioning
confidence: 99%
See 1 more Smart Citation
“…The previously validated SIERRA Monte Carlo code system [8][9][10][11] was modified to accommodate the measurement geometry required in this investigation. Figure 1 illustrates the simulated acquisition geometry utilized.…”
Section: Iia Monte Carlo Simulationsmentioning
confidence: 99%
“…Each cylinder that was evaluated extended infinitely in the z direction. Cylinders composed of water, polymethyl methacrylate ͑PMMA͒, and polyethylene, each with diameters of 10,15,20,25,30,35,40,45, and 50 cm, were studied. A divergent x-ray beam emanating from a point x-ray source was simulated, and the beam width ͑along z͒ at the isocenter was 0.01 mm.…”
Section: Iia Monte Carlo Simulationsmentioning
confidence: 99%
“…These sPSFs were reflected in order to obtain sPSFs for -60 degrees to 0 degrees incidence. We validated our sPSFs by comparing the data for zero degrees to data from Boone et al [23]. We also compared our non-zero degree incidence sPSFs to data from Sechopoulos et al [24] We found good agreement in both cases.…”
Section: Simulationmentioning
confidence: 69%
“…The Monte Carlo technique has been widely applied to studies on the influence of breast in imaging examinations [18][19][20] and the calculation of doses resulting from computed Oliveira et al Influence of female breasts in scintigraphy tomographies 21 or radiotherapy 22 . Studies on the Monte Carlo technique have also been very valuable in the area of nuclear medicine 23 .…”
Section: Discussionmentioning
confidence: 99%