The objective of this study was to investigate safety and feasibility of autologous bone marrow mononuclear cells (BMMNC) transplantation in ST elevation myocardial infarction (STEMI), comparing anterograde intracoronary artery (ICA) delivery with retrograde intracoronary vein (ICV) approach. An open labeled, randomized controlled trial of 30 patients admitted with STEMI was used. Patients were enrolled if they 1) were successfully reperfused within 24 h from symptoms onset and 2) had infarct size larger than 10% of the left ventricle (LV). One hundred million BMMNC were injected in the infarct-related artery (intraarterial group) or vein (intravenous group), 1% of which was labeled with Tc 99m -hexamethylpropylenamineoxime. Cell distribution was evaluated 4 and 24 h after injection. Baseline MRI was performed in order to evaluate microbstruction pattern. Baseline radionuclide ventriculography was performed before cell transfer and after 3 and 6 months. All the treated patients were submitted to repeat coronary angiography after 3 months. Thirty patients (57 ± 11 years, 70% males) were randomly assigned to ICA (n = 14), ICV (n = 10), or control (n = 6) groups. No serious adverse events related to the procedure were observed. Early and late retention of radiolabeled cells was higher in the ICA than in the ICV group, independently of microcirculation obstruction. An increase of EF was observed in the ICA group (p = 0.02) compared to baseline. Injection procedures through anterograde and retrograde approaches seem to be feasible and safe. BMMNC retention by damaged heart tissue was apparently higher when the anterograde approach was used. Further studies are required to confirm these initial data.
Our results showed that Tc-99m HMPAO can be used to label ABMMN cells for in vivo cell visualization, and that brain SPECT imaging with labeled ABMMN cells is a feasible noninvasive method for studying the fate of transplanted cells in vivo. Additionally, our findings demonstrate the localization of these intra-arterially injected cells.
Background. Placing the left ventricular (LV) lead in a viable segment with the latest mechanical activation (vSOLA) may be associated with optimal cardiac resynchronization therapy (CRT) response. We assessed the role of gated SPECT myocardial perfusion imaging (gSPECT MPI) in predicting clinical outcomes at 6 months in patients submitted to CRT.
Background. Glomerular filtration rate (GFR) is usually estimated from equations using serum creatinine (sCr), with adjustment for gender, age, and race (black or nonblack). The Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) is the preferred equation for adults, but it was validated for the United States population. We intended to evaluate if the race-ethnicity adjustment proposed for the sCr-based CKD-EPI equations is appropriate for the Brazilian population. Methods. CKD outpatients had blood samples collected for determination of sCr and serum cystatin C (sCys) levels. GFR was measured (mGFR) by plasma clearance of 51Cr-EDTA and used as the reference. We compared values of mGFR and estimated GFR (eGFR) by CKD-EPI equations based on sCr (eGFRCr) and on the combination of sCr and sCys (eGFRCr-Cys). For African Brazilian patients, eGFR was calculated either without or with race adjustment. Accuracy was considered acceptable if the difference between the values of eGFR and mGFR was ≤30% (P30). Results. 100 patients were enrolled (58 ± 14 years, 46% male, 39% white and 61% African Brazilian). Mean mGFR was 46.7 ± 29.2 ml/min/1.73 m2. Mean eGFRCr and eGFRCr-Cys without race adjustment were 47.8 ± 30.1 ml/min/1.73 m2 and 46.4 ± 30.3 ml/min/1.73 m2, respectively. The corresponding P30 accuracy values were 79.0% and 83.0%. In the African Brazilian subgroup, values for mean mGFR and eGFRCr either without or with race adjustment were 49.8 ± 32.2 ml/min/1.73 m2, 50.4 ± 32.7 ml/min/1.73 m2, and 58.4 ± 37.9 ml/min/1.73 m2 (P<0.001 vs. mGFR), respectively. P30 accuracy values for eGFRCr either without or with race adjustment were 75.4% and 67.2%, respectively. Conclusions. The use of CKD-EPI equations without race-ethnicity adjustment seems more appropriate for the Brazilian population.
Dementia with Lewy bodies (DLB) is the second most common cause of dementia. The diagnosis of DLB is particularly important because these patients show good response to cholinesterase inhibitors. Clinical and neuroimaging criteria for DLB have not been acceptable for predictive accuracy. We report a case of progressive dementia in which the differentiation of DLB and Alzheimer disease (AD) on the basis of clinical criteria alone was not possible. The patient was admitted to the hospital because he became worse after he had started treatment for severe AD. Both MRI and brain magnetic resonance spectroscopy were normal. The patient underwent myocardial scintigraphy with I-123 MIBG showing marked reduction in cardiac MIBG accumulation. The heart to mediastinum ratio of MIBG uptake was impaired in both early and delayed images. FDG-PET scan before and after activation with a visual attention task showed occipital cortex hypometabolism as compared with AD and a normal control. This case illustrates the value of combining activated brain FDG PET and cardiac MIBG. The association of these 2 techniques could be used as a potential diagnostic tool in a patient with dementia misdiagnosed as AD.
Physical cardiovascular examination, particularly cardiac auscultation, is one of the most difficult clinical skills for students during their medical training. Studies suggest that the use of technologies such as digital stethoscope increase the accuracy of clinical examination, however, its impact on the teaching of cardiac auscultation for undergraduate students of medicine is not known. The objective is to demonstrate the usefulness of the digital stethoscope compared to traditional methods as a tool in the teaching of auscultatory skills. nterventional, longitudinal, controlled, unicenter and randomized study. Thirty-eight medicine students were enrolled for a cardiovascular semiology course lasting eight weeks. The course program included lectures and bedside practice in Cardiology wards. In the practical lessons, the students were randomized into two groups: 1) (n = 21) digital stethoscope (Littmann® Model 3200, 3M); and 2) (n = 17) conventional stethoscopes. A pre-training evaluation was conducted through a test using the software Heart Sounds®, which was repeated after the course. The average scores were compared by paired T test and unpaired T test. It is observed that, at the end of the course, there was a significantly greater improvement in the group that used the digital stethoscope (51.9%) compared to the group using the conventional stethoscope (29.5%). Short-term interventions for cardiac semiology teaching are able to contribute significantly to improving proficiency in the identification of heart sounds. The use of digital stethoscope proved to be a positive factor in teaching these skills.
Cardiac sarcoidosis (CS) is a rare and potentially fatal condition, characterized by the presence of non-necrotizing granulomatous inflammation and concomitant fibrosis. A variety of clinical manifestation has been described, such as conduction disorders, ventricular arrythmias, congestive heart failure and sudden cardiac death, making a prompt diagnosis and early treatment desirable. Endomyocardial biopsy is the gold-standard diagnostic test, but has a low sensitivity due to the multifocal aspect of the disease. Advanced imaging modalities, such as cardiac magnetic resonance and positron emission tomography (PET) with 18F-fluorodeoxyglucose are now part of the diagnostic criteria and also assist in determining treatment response. However, the interpretation of those studies can be challenging and needs to be made by specialists, as the misdiagnosis could be harmful for the patient. This article describes the pathophysiology of CS and advanced imaging modalities (with a major focus on PET) that should be considered for diagnostic approach and therapy monitoring. Also, newer clinical trials evaluating treatment strategies are described.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
334 Leonard St
Brooklyn, NY 11211
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.