Roll angle measurement system based on differential plane mirror interferometer

Abstract: A precision roll angle measurement system based on differential plane mirror interferometer (DPMI) is proposed and the measurement principle has been analyzed theoretically in detail. This system uses DPMI with wedgy angle prism and wedgy angle reflector to produce diagonal symmetry of the two frequency beams. The residual of nanopositioning stage and roll angle system is less than 1 μrad, which has verified the correctness of the measuring principle. As result, the stability of the roll angle measurement syst… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(7 citation statements)
references
References 0 publications
0
7
0
Order By: Relevance
“…In traditional interferometer solutions, in order to be able to measure angles, the displacement is usually first calculated using the phase, and then the angle is solved [ 120 ].…”
Section: High-precision With Single Axismentioning
confidence: 99%
See 1 more Smart Citation
“…In traditional interferometer solutions, in order to be able to measure angles, the displacement is usually first calculated using the phase, and then the angle is solved [ 120 ].…”
Section: High-precision With Single Axismentioning
confidence: 99%
“…In traditional interferometer solutions, in order to be able to measure angles, the displacement is usually first calculated using the phase, and then the angle is solved [120]. In traditional interferometer solutions, in order to be able to measure angles, the displacement is usually first calculated using the phase, and then the angle is solved [120].…”
Section: (B) Heterodyne Interferencementioning
confidence: 99%
“…Extensive research on HIFs has been carried out and published, whereas HIFs are utilized for displacement measurements by Lawall et al [7], Gillmer et al [8], Yan et al [9], and Yu et al [10]. Other publications, such as Shi et al [11] or Jin et al [12], use heterodyne multi-beam interferometers for straightness and roll angle measurements. All the mentioned publications, except for Jin et al, use optical setups based on the classic Michelson interferometer design.…”
Section: State Of the Artmentioning
confidence: 99%
“…Some improvements are reported to solve this problem. A wedge prism and a wedge mirror are set in the interferometer so that the roll displacement of the wedge prime will induce an OPL change in the measuring arm [14,15]. This method detects the phase shift that is caused by the change of OPL.…”
Section: Introductionmentioning
confidence: 99%