1981
DOI: 10.1080/01483918108059966
|View full text |Cite
|
Sign up to set email alerts
|

Resolution of the Optical Isomers of Underivatisized Amino Acids on Chemically Bonded Chiral Phases by Ligand Exchange Chromatography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

2
19
0

Year Published

1988
1988
2014
2014

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 73 publications
(21 citation statements)
references
References 26 publications
2
19
0
Order By: Relevance
“…Chiral ligand exchange HPLC was performed on a column (4.6 × 120 mm) containing (S)-pipecolic acid chemically bound to a silica-based packing material following a procedure used for attachment of (S)-proline. 20 The column was thermostated at 50°C and eluted at 1 ml/min with an aqueous solution of KH 2 PO 4 (50 mM; pH 4.6) containing 0.1 mM CuSO 4 . The HPLC instrument used for the analyses consisted of a Waters M510 pump, a Waters U6K injector, and a Waters M991 Photodiode Array Detector with a detection wavelength of 225 nm.…”
Section: Chiral Liquid Chromatographymentioning
confidence: 99%
“…Chiral ligand exchange HPLC was performed on a column (4.6 × 120 mm) containing (S)-pipecolic acid chemically bound to a silica-based packing material following a procedure used for attachment of (S)-proline. 20 The column was thermostated at 50°C and eluted at 1 ml/min with an aqueous solution of KH 2 PO 4 (50 mM; pH 4.6) containing 0.1 mM CuSO 4 . The HPLC instrument used for the analyses consisted of a Waters M510 pump, a Waters U6K injector, and a Waters M991 Photodiode Array Detector with a detection wavelength of 225 nm.…”
Section: Chiral Liquid Chromatographymentioning
confidence: 99%
“…Chiral ligand exchange HPLC was performed on a column (4.6 × 120 mm) containing (S)-pipecolic acid chemically bound to a silica-based packing material following a procedure used for attachment of (S)-proline. 31 The column was connected to an HPLC instrumentation consisting of a Waters M510 pump, a Waters UK6 injector, and a Waters M991 Photodiode Array Detector with a detection wavelength of 254 nm. The column was thermostated at 50°C and eluted with an aqueous solution of KH 2 PO 4 (50 mM; pH 4.6) containing 20 µM CuSO 4 at 1.0 ml/min.…”
Section: Chiral Liquid Chromatographymentioning
confidence: 99%
“…The bonded support was loaded with Cu 2 § and racemic amino acids could be'resolved into enantiomers. 67 Other amino acids were incorporated in the CSP and compounds like enantiomers of hydroxy acids, amino acid derivatives and dipeptides could be separated. ~ Mobile phases were aqueous solvents containing Cu 2 § Besides amino acids, other compounds capable of forming ligand-exchange complexes have been incorporated in the CSP, such as tartaric acids.…”
Section: Ligand-exchange Phasesmentioning
confidence: 99%