Repeatability and Agreement of 2 Scheimpflug Analyzers in Measuring the Central Corneal Thickness and Anterior Chamber Angle, Volume, and Depth

Abstract: The measurements may be considered substantially stable for each corneal tomography and each variable, but the 2 corneal tomographies do not produce statistically equivalent measurements.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
13
1
1

Year Published

2012
2012
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 18 publications
(17 citation statements)
references
References 20 publications
2
13
1
1
Order By: Relevance
“…We used the built-in measurement tool and performed a plausibility check for inappropriate values. The built-in measurement tool reliably measures the ACA, 26 but coefficient of repeatability was reported to be 65.458. 27 This means that 95% of the repeated measures were within a difference of 5.458.…”
Section: Discussionmentioning
confidence: 99%
“…We used the built-in measurement tool and performed a plausibility check for inappropriate values. The built-in measurement tool reliably measures the ACA, 26 but coefficient of repeatability was reported to be 65.458. 27 This means that 95% of the repeated measures were within a difference of 5.458.…”
Section: Discussionmentioning
confidence: 99%
“…Some studies have assessed the repeatability of various anterior segment measurements provided by the same Scheimpflug imaging-based system as that used in the current study [6][7][8][9][10], with most reporting high levels of consistency [10][11][12][13][14]. However, few works have studied the repeatability of IA measurements [8], and to date, there is no study validating the consistency of measurements provided by the glaucoma mode of the Scheimpflug imagingbased system used in our series.…”
Section: Discussionmentioning
confidence: 99%
“…One example of a system providing non-invasive measurement of the IA is the Sirius ® system (Costruzione Strumenti Oftalmici [CSO], Florence, Italy), a non-contact 3D rotating Scheimpflug camera combined with a Placido ring that provides different anatomical measurements of the anterior segment. While there is strong scientific evidence of the consistency and repeatability of anterior segment measurements provided by this system in healthy and even pathological eyes [6][7][8][9][10][11][12][13][14][15], evidence of the repeatability of IA measurements is limited [8]. Likewise, to the best of our knowledge, no studies have evaluated and compared the consistency of IA measurements at different nasal and temporal meridians using this device.…”
Section: Introductionmentioning
confidence: 99%
“…8,17,18 Yine de çalışmamızda kontrol grubunun bulunmayışı bu açıdan kısıtlayıcı bir unsur olarak değerlendirilebilir. Ancak PAKŞ grubunda dahi olsa tanı konulan olguların, periferik iridotomi uygulamaksızın kontrol grubu olarak takibinin etik açıdan doğru olmayacağı düşünülmüştür.…”
Section: Discussionunclassified