2018
DOI: 10.1016/j.est.2017.12.013
|View full text |Cite
|
Sign up to set email alerts
|

Reliability assessment of generating systems containing wind power and air separation unit with cryogenic energy storage

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
10
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 37 publications
0
10
0
Order By: Relevance
“…This is shown in Figure 6 through the red line in the graph of the superimposed generation and load model. The risk model represents the superimposition of the generation and the load model from which the LOLE reliability index is calculated [20]. The LOLE is the sum of the individual algebraic differences between the load level and the generation capacity at the points where the load level exceeds the generation capacity.…”
Section: The Generation Model Load Model and The Risk Modelmentioning
confidence: 99%
See 2 more Smart Citations
“…This is shown in Figure 6 through the red line in the graph of the superimposed generation and load model. The risk model represents the superimposition of the generation and the load model from which the LOLE reliability index is calculated [20]. The LOLE is the sum of the individual algebraic differences between the load level and the generation capacity at the points where the load level exceeds the generation capacity.…”
Section: The Generation Model Load Model and The Risk Modelmentioning
confidence: 99%
“…In addition, the load system has a record of the consumers' hourly load usage level, hence, also 8736 values. Since both the generation capacity and the load level have the same graphic units (MW versus hours), it becomes easy to superimpose The risk model represents the superimposition of the generation and the load model from which the LOLE reliability index is calculated [20]. The LOLE is the sum of the individual algebraic differences between the load level and the generation capacity at the points where the load level exceeds the generation capacity.…”
Section: The Generation Model Load Model and The Risk Modelmentioning
confidence: 99%
See 1 more Smart Citation
“…These systems, integrating renewable energy generation and storage, are able to follow a guaranteed production program similarly to a conventional generating unit and, therefore, to participate in the electricity market, overcoming the dispatching priority method used for subsidizing the generation of electricity from renewable sources. Some works have been presented which use a cryogenic process for energy storage also for integrating wind generation in the system [6,7]. These works use air liquefaction as an energy storage means but do not exploit the possibility of separately produce liquefied oxygen.…”
Section: Introductionmentioning
confidence: 99%
“…Noussan et al [17] proposed an optimization tool to enhance the operation of a CHP system combined with a heat pump. Zamani-Gargari et al [18] proposed a method which combined the Monte Carlo Simulation (MCS) method to assess the reliability of a wind power system with energy storage. Yang et al [19] proposed an approach to analyzing how the wind farm electrical system influenced the system when the electrical system faulted.…”
Section: Introductionmentioning
confidence: 99%