2019
DOI: 10.1016/j.bios.2018.09.096
|View full text |Cite
|
Sign up to set email alerts
|

Red light-driven photoelectrochemical biosensing for ultrasensitive and scatheless assay of tumor cells based on hypotoxic AgInS2 nanoparticles

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
30
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 47 publications
(30 citation statements)
references
References 43 publications
0
30
0
Order By: Relevance
“…In addition, QDs have been functionalized for biomedical applications. AgInS 2 was functionalized with sgc8c aptamer to sense tumor cells [ 87 ], methotrexate for drug delivery [ 88 ], and DNA for potential biomedical applications [ 89 ]. Therefore, the functionalization of these novel nanoparticles is an opportunity area with several applications.…”
Section: Sensing Schemesmentioning
confidence: 99%
“…In addition, QDs have been functionalized for biomedical applications. AgInS 2 was functionalized with sgc8c aptamer to sense tumor cells [ 87 ], methotrexate for drug delivery [ 88 ], and DNA for potential biomedical applications [ 89 ]. Therefore, the functionalization of these novel nanoparticles is an opportunity area with several applications.…”
Section: Sensing Schemesmentioning
confidence: 99%
“…The principle of electrochemical detection is to modify the electrode using nanomaterials and cancer cell specific aptamer, and CTC is bonded to aptamer (on the electrode surface), which will cause the current/electrochemiluminescence (ECL)/photoelectrochemical (PEC) signal to decrease or EC impedance spectroscopy (EIS) signal to increase [27,[92][93][94][95][96]. By establishing a linear relationship between the change and the number of CTC, the quantification can be realized.…”
Section: Electrochemical Detection Of Ctcmentioning
confidence: 99%
“…After CCRF-CEM cell is connected to aptamers on AgInS 2 NPs, the photocurrent is significantly reduced, and CTC can be detected. Its linear range is from 1.5 × 10 2 to 3.0 × 10 5 cells mL −1 , and the LOD is 16 cells mL −1 ( Figure 3C) [93]. In order to further improve the detection sensitivity, Wang et al prepared nanomaterials-plasmonic gold nanostars (AuNSs), modified sgc8c aptamer on its surface and fixed it on glassy carbon (GC) electrode.…”
Section: Direct Assaysmentioning
confidence: 99%
See 1 more Smart Citation
“…These biosensors demonstrated a linear range of 63–1.0 × 10 7 cells mL −1 and limit-of-detection of 21 cells mL −1 . Lymphoblast (CCRF-CEM) cells were also detected based on steric hindrance in a PEC biosensor (Li et al, 2019). These cells were captured using hairpin DNA targeting overexpressed protein tyrosine kinase-7 on their surface.…”
Section: Transduction Mechanismmentioning
confidence: 99%